OSHA Inspection: BUCKEYE FIRE EQUIPMENT COMPANY

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of BUCKEYE FIRE EQUIPMENT COMPANY in 110 KINGS DRIVE, KINGS MOUNTAIN, NC 28086 (NAICS 339999). OSHA activity number 313977613.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Buckeye Fire Equipment Company — free Get an email when a new federal OSHA severe-injury report for Buckeye Fire Equipment Company is published. One employer, no account, unsubscribe in one click.
Site address
110 KINGS DRIVE
City
KINGS MOUNTAIN
State
NC
ZIP
28086
Mailing
P.O. BOX 428, KINGS MOUNTAIN, NC 28086
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
SIC code (legacy)
3999
Employees
200
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

95012901

Serious 1 instance 1 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $4,000 · Current $4,000
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish
employment and a place of employment which were free from
recognized hazards that were causing or likely to cause death or
serious physical harm to employees in that employees were exposed
to struck-by hazards:
a)at the stainless steel production area, on or about
October 29, 2009, employee was not adequately protected
from struck-by injuries during the pressurized leak
testing of thirty pound fire extinguisher bodies in the
event that a fire extinguisher body explosively failed.
Among other methods, two applicable and feasible methods of
abatement is to test the thirty pound fire extinguisher bodies
hydrostatically or pressure leak test thirty pound fire
extinguisher bodies in an vault or room designed to contain
the potential energy of an explosive failure and view the test
remotely by camera if necessary.

View Buckeye Fire Equipment Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313977613.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.