PLAINFIELD, NJ ·
OSHA Inspection: NEW JERSEY HARDWOODS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEW JERSEY HARDWOODS, INC. in 1340 W. FRONT ST., PLAINFIELD, NJ 07063 (NAICS 321999). OSHA activity number 313981896.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW JERSEY HARDWOODS, INC.
- Site address
- 1340 W. FRONT ST.
- City
- PLAINFIELD
- State
- NJ
- ZIP
- 07063
- Mailing
- 1340 W. FRONT ST., PLAINFIELD, NJ 07063
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- SIC code (legacy)
- 2499
- Employees
- 20
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 22, 2010
- Abate by
- Dec 6, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recogn ized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of fire/explosion haz ard: a/ New Jersey Hardwoods/Plainfield NJ Site - Plant/Production Areas: Dust C ollection System/Equipment operating in Class II combustible (wood) dust locatio ns: Employees exposed to the hazard of fire/explosion resulting from the potenti al ignition of Class II combustible dust, in that, the dust collection system, m achinery and/or equipment does not meet the requirements specified in NFPA 664. At the time of this inspection the emplr. could not provide documented informati on to confirm that the Dust Collection System/Cyclone has 1/ a spark detection s ystem 2/ a fire suppression system 3/ that all components of the dust collection syste m were of non-combustible materials, e.g., non-combustible flexible connectors/h oses 4/ documentation/retention of records specific to the dust collection syste m on inspections, testing, maintenance, service provider, etc. 5/ documentation/ retention of the training provided to employees/supervisors involved in the oper ation, maintenance, equipment, etc. 6/ documentation/retention of records on the dust collection system, e.g., manufacturer, safety manual, etc. Feasible abatem ent method: Among other methods, one feasible and acceptable means of abatement would be to comply with the guidelines outlined in the National Fire Protection Association (NFPA) 664 Standard for the Prevention of Fires and Explosions in Wo od Processing and Woodworking Facilities (2007 Edition.) Reference: National Fir e Protection Association NFPA 664 (2007 Edition) Standard for the Prevention of Fire/Explosion in Wood Processing and Woodworking Faciliti es. Sections:664 8.2.2.6.2 - Spark Detection System. 664 8.2.2.5.3 - Fire Suppre ssion System. 664 10.2.1 and 664 10.2.2 - Inspection. Testing and Maintenance. 6 64 10.2 and 10.3 - Retention of required dust collection records. Observed on/or about 08/16/10.
1910.22 A01
- Issued
- Oct 22, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $1,500 · Current $1,500
1910.37 A02
- Issued
- Oct 22, 2010
- Abate by
- Oct 27, 2010
- Penalty
- Initial $1,500 · Current $1,500
1910.37 A03
- Issued
- Oct 22, 2010
- Abate by
- Oct 27, 2010
- Penalty
- Initial $0 · Current $0
1910.213 H01
- Issued
- Oct 22, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $1,500 · Current $1,500
1910.213 H03
- Issued
- Oct 22, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $0 · Current $0
1910.213 H04
- Issued
- Oct 22, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $0 · Current $0
1910.213 I01
- Issued
- Oct 22, 2010
- Abate by
- Nov 15, 2010
- Penalty
- Initial $750 · Current $750
1910.215 B09
- Issued
- Oct 22, 2010
- Abate by
- Nov 15, 2010
- Penalty
- Initial $750 · Current $750
1910.219 D01
- Issued
- Oct 22, 2010
- Abate by
- Nov 15, 2010
- Penalty
- Initial $750 · Current $750
1910.219 E01 I
- Issued
- Oct 22, 2010
- Abate by
- Nov 15, 2010
- Penalty
- Initial $0 · Current $0
1910.303 G01 II
- Issued
- Oct 22, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $750 · Current $750
More inspections at NEW Jersey Hardwoods, INC.
View NEW Jersey Hardwoods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 313981896.