BONITA SPRINGS, FL ·
OSHA Inspection: FLUID FLOW OF FL. DBA SYSTEM COMPONENTS CORP.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FLUID FLOW OF FL. DBA SYSTEM COMPONENTS CORP. in 25500 WELLFIELD RD., BONITA SPRINGS, FL 34135 (NAICS 541990). OSHA activity number 314019027.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID FLOW OF FL. DBA SYSTEM COMPONENTS CORP.
- Site address
- 25500 WELLFIELD RD.
- City
- BONITA SPRINGS
- State
- FL
- ZIP
- 34135
- Mailing
- 7731 SE 59TH COURT, OCALA, FL 34472
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541990
- SIC code (legacy)
- 7389
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 11, 2010
- Abate by
- Mar 16, 2010
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employees were exposed to the hazard of being burned by a flash fire. a) Site - Service Center Lift Station 25500 Wellfield Rd. Bonita Springs, Fl. 34135 Employees were exposed to being burned from a flash fire when flammable gases and/or vapors were ignited during a demonstration of a fluid level radar transmitter, on or about 11/05/09. Among other methods one feasible and acceptable abatement would be to: 1. In order to prevent explosions and/or employee overexposures, monitoring must be done with a calibrated, direct reading instrument for the presence of flammable gases and vapors after the opening of sewer valves and prior to and during the demonstration and use of non- intrinsically safe equipment such as but not limited to fluid level radar transmitters. 2. Continuous forced air ventilation is to be used prior to the use of non- intrinsically safe equipment such as but not limited to fluid level radar transmitters if the presence of flammable gas or vapor is detected.
Recent events (2)
- · I (S) $1750.00
- · Z (S) $3500.00
1910.307 B
- Issued
- Mar 11, 2010
- Abate by
- Mar 16, 2010
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- · I (S) $1750.00
- · Z (S) $3500.00
More inspections in this industry (NAICS 541990)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314019027.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.