OSHA Inspection: UNIVERSAL COLD STORAGE & TRUCKING, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of UNIVERSAL COLD STORAGE & TRUCKING, LLC in 1601 PIONEERS BLVD, LINCOLN, NE 68502 (NAICS 493120). OSHA activity number 314055641.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Cold Storage & Trucking, LLC — free Get an email when a new federal OSHA severe-injury report for Universal Cold Storage & Trucking, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1601 PIONEERS BLVD
City
LINCOLN
State
NE
ZIP
68502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
SIC code (legacy)
4222
Employees
70
Ownership type
A
Industry flags
Manufacturing health.

6 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 05 10 instances 70 exposed
Issued
Oct 29, 2010
Abate by
Dec 1, 2010
Penalty
Initial $1,250 · Current $875 Reduced
29 CFR 1910.119(d)(3)(ii):
Universal Cold Storage & Trucking, LLC - Lincoln, NE - The employer did
not document that
the equipment in the process complied with recognized and generally
accepted good engineering
practices (RAGAGEP).
Unlabeled and/or improperly labeled valves, pressure relief valves, and
piping
including, but not limited to RV #179 and RV #237 did not comply with
RAGAGEP such as International Institute of Ammonia Refrigeration (IIAR)
Bulletin #114 and facility mechanical integrity program.
Abatement certification is required for this violation. The abatement
certification sheet is
enclosed with the citations.
Recent events (2)
  • — I (S) $875.00
  • — Z (S) $1250.00

1910.119 E05

Serious Gravity 10 23 instances 70 exposed
Issued
Oct 29, 2010
Abate by
Jan 31, 2011
Penalty
Initial $2,500 · Current $1,750 Reduced
29 CFR 1910.119(e)(5):
Universal Cold Storage & Trucking, LLC - Lincoln, NE - The employer did
not establish a
system to promptly address the process hazard analysis team's findings and
recommendations.
Abatement certification and abatement documentation is required for this
violation. The
documentation should include written verification of abatement, applicable
measurements or
monitoring results, and photographs or videos which you believe will be
helpful. The abatement
certification sheet is enclosed with the citations.ion
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $2500.00

1910.119 J02

Serious Gravity 05 1 instance 70 exposed
Issued
Oct 29, 2010
Abate by
Jan 31, 2011
Penalty
Initial $1,250 · Current $875 Reduced
29 CFR 1910.119(j)(2):
Universal Cold Storage, LLC - Lincoln, NE - The employer did not establish
and implement
written procedures to maintain the on-going mechanical integrity of
process equipment.
Facility mechanical integrity program did not include written procedures to
address the frequency of non-destructive and visual inspections of process
equipment including, but not limited to pressure vessels and piping.
Abatement certification is required for this violation. The abatement
certification sheet is
enclosed with the citations.
Recent events (2)
  • — I (S) $875.00
  • — Z (S) $1250.00

1910.119 J04 I

Serious Gravity 05 3 instances 70 exposed
Issued
Oct 29, 2010
Abate by
Jan 31, 2011
Penalty
Initial $1,250 · Current $875 Reduced
29 CFR 1910.119(j)(4)(i):
Universal Cold Storage & Trucking, Inc. - Lincoln, NE - Inspection and
tests were not peformed
on process equipment to maintain its mechanical integrity.
Inspection and non-destructive thickness testing for process piping and
pressure
vessels had not been conducted per RAGAGEP such as API 570, API RP 575,
ASME/ANSI B31.3 and facility safety inspection checklists.
Abatement certification is required for this violation. The abatement
certification sheet is
enclosed with the citations.
Recent events (2)
  • — I (S) $875.00
  • — Z (S) $1250.00

1910.119 J04 III

Serious Gravity 10 25 instances 70 exposed
Issued
Oct 29, 2010
Abate by
Jan 31, 2011
Penalty
Initial $2,500 · Current $1,750 Reduced
29 CFR 1910.119(j)(4)(iii):
Universal Cold Storage & Trucking, LLC - Lincoln, NE - The frequency of
inspections
and tests
of process equipment to maintain its mechanical integrity, was not
consistent with applicable
manufacturers' recommendations and good engineering practices, or more
frequently if
determined to be necessary by prior operating experience.
Pressure relief valves for process equipment including, but not limited to
compressors, pressure vessels and associated piping, had not been tested
and/or
replaced at least every five years to comply with RAGAGEP such ASHRAE-15
and the facility mechanical integrity program.
Abatement certification and abatement documentation is required for this
violation. The
documentation should include written verification of abatement, applicable
measurements or
monitoring results, and photographs or videos which you believe will be
helpful. The abatement
certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $2500.00

1910.119 J05

Serious Gravity 10 5 instances 70 exposed
Issued
Oct 29, 2010
Abate by
Jan 31, 2011
Penalty
Initial $2,500 · Current $1,750 Reduced
29 CFR 1910.119(j)(5):
Universal Cold Storage & Trucking, LLC - Lincoln, NE - The employer did
not correct
deficiencies in equipment that were outside acceptable limits (as defined
by the process safety
information in paragraph (d) of this section) before further use or in a
safe and timely manner.
A) Emergency exhaust of 11,147 cfm in south engine room does not meet the
minimum requirements per IIAR-2-1999 and company mechanical integrity
program inspection checklist.
B) Relief discharge piping on equipment including, but not limited to the
economizer (EC-HSC-3) and the surge vessel (SV-3 for AU-37) is too small
and
length exceeds allowable length per 1992, 2000 relief piping code and
facility
inspection tracking report.
Abatement certification and abatement documentation is required for this
violation. The
documentation should include written verification of abatement, applicable
measurements or
monitoring results, and photographs or videos which you believe will be
helpful. The abatement
certification sheet is enclosed with the citations.
Abatement certification is required for this violation. The abatement
certification sheet is
enclosed with the citations.
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $2500.00