ADAMS, NE —
OSHA Inspection: E ENERGY ADAMS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E ENERGY ADAMS LLC in 13238 EAST ASPEN ROAD, ADAMS, NE 68301 (NAICS 325193). OSHA activity number 314056276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E ENERGY ADAMS LLC
- Site address
- 13238 EAST ASPEN ROAD
- City
- ADAMS
- State
- NE
- ZIP
- 68301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325193
- SIC code (legacy)
- 2869
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
1910.119 E03 V
- Issued
- Jan 22, 2011
- Abate by
- Sep 2, 2011
- Penalty
- Initial $1,250 · Current $875 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The employer did not ensure that the process hazard analysis included the identification of all facility siting which would have a likely potential for catastrophic consequences in the workplace: 13238 East Aspen Road, Adams, NE 68301 (Distillation Area): The employer did not ensure that process hazard analysis included the identification, evaluation, and control of the accumulation of highly hazardous chemicals (HHCs) in sumps, pits or open ditches, which would have a likely potential for catastrophic consequences in the workplace. In the distillation area, there is a sump in the NW corner of the burm area. This information was not included in the most recent process hazard analysis (PHA), which was completed in 2007. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- — P (S) $875.00
- — I (S) $875.00
- — Z (S) $1250.00
1910.119 E03 VI
- Issued
- Jan 20, 2011
- Abate by
- Sep 2, 2011
- Penalty
- Initial $1,250 · Current $875 Reduced
General-duty citation text
29 CFR 1910.119 (e)(3)(vi): The employer did not ensure that the process hazard analysis (PHA) addressed human factors: 13238 East Aspen Road, Adams, NE 68301 (Jobsite): The employer did not ensure that the process hazard analysis (PHA) addressed human factors. The process hazard analysis (PHA) was completed on September 19, 2007. However, the PHA did not address human factors to identify error-likely situations including, but not limited to; having less than the minimum number of required operators available to operate the process. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- — P (S) $875.00
- — I (S) $875.00
- — Z (S) $1250.00
1910.119 F01
- Issued
- Jan 20, 2011
- Abate by
- Mar 31, 2012
- Penalty
- Initial $1,250 · Current $875 Reduced
General-duty citation text
29 CFR 1910.119 (f)(1): The employer did not develop or implement written operation procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressed at least the following elements included in this subpart [A-G]: 13238 East Aspen Road, Adams, NE 68301 (Jobsite): The employer did not develop or implement written operation procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressed at least the following elements included in this subpart including, but not limited to; emergency shutdown. The process hazard analysis (PHA) was completed on September 19, 2007. However, neither the PHA or any other policies and/or procedures were available for overriding or by-passing equipment at the facility. This includes, but is not limited to; written procedures for controlling situations where safety mechanisms might be overridden. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (3)
- — P (S) $875.00
- — I (S) $875.00
- — Z (S) $1250.00
More inspections at E Energy Adams LLC
View E Energy Adams LLC's full OSHA safety record →
More inspections in this industry (NAICS 325193)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314056276.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.