EAST BUTLER, PA —
OSHA Inspection: STANDARD BENT GLASS CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STANDARD BENT GLASS CORPORATION in 136 LINCOLN AVENUE, EAST BUTLER, PA 16029 (NAICS 327215). OSHA activity number 314111188.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STANDARD BENT GLASS CORPORATION
- Site address
- 136 LINCOLN AVENUE
- City
- EAST BUTLER
- State
- PA
- ZIP
- 16029
- Mailing
- P.O. BOX 469, BUTLER, PA 16003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- SIC code (legacy)
- 3231
- Employees
- 70
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
19 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
- Penalty
- Initial $1,785 · Current $1,448 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to deficiencies to the hoists by not conducting frequent and periodic inspections: (a)Facility, 136 Lincoln Avenue, East Butler, PA: On or about 10/05/10 the employer did not conduct inspections of the upper limit devices of hoists at the beginning of each shift. The hoists in the facility are used daily by employees to move materials. (b)Facility, 136 Lincoln Avenue, East Butler, PA: On or about 10/05/10 the employer did not conduct periodic inspections, with records, of the hoists used in the facility. Among other methods, one feasible and acceptable abatement method to correct these hazards is to follow the manufacturer's recommendations for daily inspections of the upper limit device and to conduct periodic inspections and maintain records to provide a basis for a continuing evaluation.
Recent events (3)
- — P (S) $1448.00
- — I (S) $1448.00
- — Z (S) $1785.00
1910.147 C06 IA
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
- Penalty
- Initial $1,785 · Current $1,448 Reduced
Recent events (2)
- — I (S) $1448.00
- — Z (S) $1785.00
1910.147 C06 II
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C07 I
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
- Penalty
- Initial $1,785 · Current $1,448 Reduced
Recent events (2)
- — I (S) $1448.00
- — Z (S) $1785.00
1910.184 D
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
- Penalty
- Initial $1,785 · Current $1,448 Reduced
Recent events (2)
- — I (S) $1448.00
- — Z (S) $1785.00
1910.184 E03 II
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.184 E01
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
- Penalty
- Initial $2,975 · Current $2,080 Reduced
Recent events (2)
- — I (S) $2080.00
- — Z (S) $2975.00
1910.184 E02 II
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
Recent events (2)
- — I (S)
- — Z (S)
1910.213 C03
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
- Penalty
- Initial $2,380 · Current $2,024 Reduced
Recent events (2)
- — I (S) $2024.00
- — Z (S) $2380.00
1910.213 G01
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
- Penalty
- Initial $4,900 · Current $1,666 Reduced
Recent events (2)
- — I (S) $1666.00
- — Z (S) $4900.00
1910.213 G03
- Issued
- Nov 1, 2010
- Abate by
- Nov 5, 2010
1910.213 I01
- Issued
- Nov 1, 2010
- Abate by
- Nov 4, 2010
- Penalty
- Initial $2,380 · Current $2,080 Reduced
Recent events (2)
- — I (S) $2080.00
- — Z (S) $2380.00
1910.215 A04
- Issued
- Nov 1, 2010
- Abate by
- Nov 5, 2010
- Penalty
- Initial $1,785 · Current $1,448 Reduced
Recent events (2)
- — I (S) $1448.00
- — Z (S) $1785.00
1910.215 B09
- Issued
- Nov 1, 2010
- Abate by
- Nov 5, 2010
1910.215 D03
- Issued
- Nov 1, 2010
- Abate by
- Nov 5, 2010
1910.303 B02
- Issued
- Nov 1, 2010
- Abate by
- Nov 19, 2010
1910.305 G01 IVA
- Issued
- Nov 1, 2010
- Abate by
- Nov 19, 2010
1910.305 B01 I
- Issued
- Nov 1, 2010
- Abate by
- Nov 8, 2010
1910.1200 H03 IV
- Issued
- Nov 1, 2010
- Abate by
- Jan 31, 2011
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Standard Bent Glass Corporation
View Standard Bent Glass Corporation's full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314111188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.