Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SNF HOLDING CO

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SNF HOLDING CO in 10 STAUFFER INDUSTRIAL PARK, TAYLOR, PA 18517 (NAICS 325188). OSHA activity number 314158114.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SNF Holding CO for free Get an email when a new federal OSHA severe-injury report for SNF Holding CO is published. One employer, no account, unsubscribe in one click.
Establishment
SNF HOLDING CO
Site address
10 STAUFFER INDUSTRIAL PARK
City
TAYLOR
State
PA
ZIP
18517
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
SIC code (legacy)
2819
Employees
9
Ownership type
A

3 citations on file for this inspection.

1910.119 D03 IB

Serious Gravity 01 1 instance 2 exposed
Issued
Dec 27, 2010
Abate by
Jan 31, 2011
Penalty
Initial $1,125 · Current $844 Reduced
29 CFR 1910.119(d)(3)(i)(B):  Process safety information pertaining to the
equipment in the
process did not include the piping and instrument diagrams (P&ID'S):
(a)  A current P&ID was not available for the dimethylamine tank piping
system
in that the selector valve for the pressure relief system was not
represented, on
or about December 1, 2010.
ABATEMENT CERTIFICATION REQUIREDATION
Recent events (2)
  • · I (S) $844.00
  • · Z (S) $1125.00

1910.119 E01

Serious Gravity 05 2 instances 2 exposed
Issued
Dec 27, 2010
Abate by
Apr 29, 2011
Penalty
Initial $1,875 · Current $1,406 Reduced
29 CFR 1910.119(e)(1):  The process hazard analysis did not identify,
evaluate, and address the
control of the hazards involved in the process:
(a)  The process hazard analysis did not identify, evaluate or control the
hazard
of flammable premix being transferred through a pipe which contained a
valve in
an area which was not considered a hazardous (classified) location, on or
about
December 1, 2010.
(b)  The process hazard analysis did not identify, evaluate or control the
hazard
of removing one pressure relief device from the dimethylamine tank and not
controlling the position of the selector valve which leads to the pressure
relief
devices, on or about October 20, 2010.
ABATEMENT CERTIFICATION REQUIREDATION
Recent events (2)
  • · I (S) $1406.00
  • · Z (S) $1875.00

1910.119 F01 IC

Serious Gravity 05 1 instance 2 exposed
Issued
Dec 27, 2010
Abate by
Jan 31, 2011
Penalty
Initial $1,500 · Current $1,125 Reduced
29 CFR 1910.119(f)(1)(i)(C):  The employer's written operating procedures
covering the steps
for each operating phase did not address temporary operations:
(a)  A temporary operating procedure to address the selector valve on the
DMA
tank when one pressure relief device was removed was not included in the
written
operating procedures, on or about December 1, 2010.
ABATEMENT CERTIFICATION REQUIREDATION
Recent events (2)
  • · I (S) $1125.00
  • · Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314158114.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.