WILKES-BARRE, PA —
OSHA Inspection: J & E SHEETMETAL LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J & E SHEETMETAL LLC in 259 OLD RIVER ROAD, WILKES-BARRE, PA 18702 (NAICS 332322). OSHA activity number 314161894.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & E SHEETMETAL LLC
- Site address
- 259 OLD RIVER ROAD
- City
- WILKES-BARRE
- State
- PA
- ZIP
- 18702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- SIC code (legacy)
- 3444
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 28, 2011
- Abate by
- May 2, 2011
- Penalty
- Initial $3,000 · Current $2,250 Reduced
Recent events (2)
- — I (S) $2250.00
- — Z (S) $3000.00
5(a)(1)
- Issued
- Mar 28, 2011
- Abate by
- May 2, 2011
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an amputation hazard from the unintentional operation of a press brake: a) In the shop area, the foot pedal (treadle) on a Roto-Die hydraulic press brake was unguarded exposing the operator and others to an amputation hazard from unintentional operation as observed on or about March 18, 2011. Among other methods, one feasible and acceptable method to abate this is to follow the safety standard: Ansi B11.2-1995, Hydraulic Power Presses, Section 6.3.9, Paragraph 4 and/or Ansi B11.3-2002, Section 6.10.3, Safety Requirements For Power Press Brakes. ABATEMENT CERTIFICATION REQUIRED In the alternative: 29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In the shop area, the unguarded foot pedal (treadle) on a Roto-Die hydraulic press brake exposed workers to an amputation hazard in the event of unintentional operation as observed on or about March 18, 2011. ABATEMENT CERTIFICATION REQUIREDATION