GRAND FORKS, ND —
OSHA Inspection: J. R. SIMPLOT COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J. R. SIMPLOT COMPANY in 3630 GATEWAY DRIVE, GRAND FORKS, ND 58203 (NAICS 311411). OSHA activity number 314172024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. R. SIMPLOT COMPANY
- Site address
- 3630 GATEWAY DRIVE
- City
- GRAND FORKS
- State
- ND
- ZIP
- 58203
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- SIC code (legacy)
- 2037
- Employees
- 395
- Ownership type
- A
Citations
20 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: (a) For employees in the dock area and exposed to struck-by hazard where the approximately ten foot high storage platform was not guarded by standard railings. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.119 D03 IB
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $5,000 · Current $5,000
0170
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information pertaining to the equipment in the process did not include the piping and instrument diagrams (P&ID's): (a) For employees engaged in Process Safety Management and associated operations, the P&ID identified as 4041.PID-09 was not accurate in that the drawing included pressure indicators, pressure control valves and piping related to pressure vessel V-3 that was not present in the actual system exposing employees to potential ammonia release. (b) For employees engaged in Process Safety Management and associated operations, the P&ID identified as 4041.PID-09 was not accurate in that the drawing included pressure indicators related to pressure vessel V-4 that were not present in the actual system exposing employees to potential ammonia release. (c) For employees engaged in Process Safety Management and associated operations, the P&ID identified as 4041.PID-09 was not accurate in that the drawing failed to include isolation valves, solenoid valves, a king valve, and the proper sequence of valves for the piping section containing solenoid valve V4.11, V10, and V4.09 with respect to pressure vessel V-4 exposing employees to potential ammonia release. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.119 D03 II
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
0170
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices: (a) For employees engaged in Process Safety Management and associated operations, four liquid anhydrous ammonia lines that were located in the compressor room making up the cooling loops for two booster compressors identified as a Mycom 5B and a Sullair 10B were not labeled as to content, pressure, or state (vapor or liquid) exposing employees to potential ammonia release. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.119 D03 III
- Issued
- Sep 28, 2010
- Abate by
- Mar 1, 2011
0170
General-duty citation text
29 CFR 1910.119(d)(3)(iii): For existing equipment designed and constructed in accordance with codes, standards, or practices that are no longer in general use, the employer did not determine and document that the equipment in the process was designed, maintained, inspected, tested, and operated in a safe manner: (a) For employees engaged in Process Safety Management and associated operations, an emergency shut-off for the machinery room equipment located immediately outside the machinery room, as required by ASHRAE 15 - 1978, 2001, 2007 and IIAR 2-2008, was not provided exposing employees to hazards or potential hazards from ammonia release. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
1910.119 J02
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $2,500 · Current $2,500
0170
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment: Mechanical integrity procedures were inadequate where they did not specify how often integrity testing preventive maintenance was to be done although some maintenance was getting done. RAGAGEP was not referenced. (a) For employees engaged in Process Safety Management and associated operations, a written procedure to maintain the on-going integrity of ammonia compressors was not established exposing employees to potential ammonia release. (b) For employees engaged in Process Safety Management and associated operations, a written procedure to maintain the on-going integrity of ammonia pumps was not established exposing employees to potential ammonia release. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.119 J05
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $5,000 · Current $5,000
0170
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (as defined by process information in 29 CFR 1910.119(d)) before further use or in a safe and timely manner: (a) For employees who operated a liquid ammonia line isolation valve located directly above the number 4 compressor which was labeled with a tag that states "Do Not Close" and has been inoperable for approximately two years. (b) For employees who operated an 8" hot gas isolation valve on the roof which has been leaking for approximately one year. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.146 C02
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) For employees who entered the dryer weekly to spray and scrape, the employer did not inform employees by posting signs or other effective means, the dryer was a permit- required confined space. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
1910.146 E01
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Current $1,500
General-duty citation text
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit: (a) For employees who entered the dryer to spray and scrape on or about April 1, 2010, where the employer did not document that the necessary measures to ensure employee safety from serious physical hazards had been completed. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $1500.00
- — Z (S)
1910.179 J03
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: (a) For employees operating the cranes in the packaging area where the cranes had not been periodically inspected since February 18, 2009. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $1500.00
- — Z (S) $1500.00
1910.212 A01
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by in-running nip points: (a) For employees operating the Line 1 box take-away conveyor after the retail blue print in the pack room and were exposed to the in-running nip point on the inward running rotating roller. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.212 A03 II
- Issued
- Sep 28, 2010
- Abate by
- Nov 1, 2010
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s)-of-operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Employees operating the Cincinnati horizontal milling machine in the machinist shop were exposed to amputation hazard from the unguarded blade. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.213 B03
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: (a) For employee operating the Delta professional radial arm saw and exposed to amputation hazard from the saw automatically restarting upon restoration of power after a power failure.ion
1910.213 H04
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: (a) For employee operating the Delta professional radial arm saw and exposed to amputation hazard from the saw not returning gently to the starting position when released by the operator.
1910.219 C02 I
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1910.219(c)(2)(i): Exposed part(s) of horizontal shafting were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) For employee operating the north end L1 dryer and exposed to the rotating shaft where the guards had been removed. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.219 C04 I
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one-half the diameter of the shaft: (a) For employees operating the southwest hopper incline take-away conveyor in the block building who were exposed to a projecting rotating shaft end which was not guarded with a non-rotating cap, exposing operators to being caught in the projecting shaft. (b) For employees operating the sliver remover conveyor at the L#1 ADR area who were exposed to a projecting rotating shaft end which was not guarded with a non-rotating cap, exposing operators to being caught in the projecting shaft. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
1910.219 F03
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed: (a) For employees operating the L1 dryer conveyor who were exposed to the unguarded chain and sprocket. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
1910.303 G02 IA
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.303(g)(2)(i)(A): Entrances to rooms and other guarded locations containing exposed live parts were not marked with conspicuous warning signs forbidding unqualified persons to enter: (a) For unauthorized employees entering the electrical room of the compressor room and exposed to electrical hazard from 120-volt electrical equipment.
1910.334 A02 II
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made: (a) For employees in the compressor room and exposed to an electrical hazard by an ungrounded fan where the connection was spliced with duct tape on or about July 13, 2010.
1910.334 A04
- Issued
- Sep 28, 2010
- Abate by
- Oct 1, 2010
General-duty citation text
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords used in highly conductive work locations, or in job locations where employees were likely to contact water or conductive liquids, were not approved for those locations: (a) For employees in the compressor room and exposed to electrical hazard by an ungrounded fan being used in a wet location on or about July 13, 2010.
1910.119 J04 I
- Issued
- Sep 28, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $25,000 · Current $25,000
0170
General-duty citation text
29 CFR 1910.119(j)(4)(i): Inspections and tests were not performed on process equipment to maintain its mechanical integrity: (a) For employees engaged in Process Safety Management and associated operations, the pressure gauges used to verify the accuracy of safety cutouts for compressors were not calibrated exposing employees to potential ammonia release. Note: This company was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained under OSHA Inspection Number 311577613, Citation 1, Item 6A issued on September 30, 2008. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (R) $25000.00
- — Z (R) $25000.00
More inspections at J. R. Simplot Company
View J. R. Simplot Company's full OSHA safety record →
More inspections in this industry (NAICS 311411)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314172024.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.