MONTGOMERY, AL —
OSHA Inspection: PROFESSIONAL FACILITIES MANAGEMENT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PROFESSIONAL FACILITIES MANAGEMENT, INC. in 1000 EASTDALE MALL (EASTERN MALL), MONTGOMERY, AL 36109 (NAICS 561790). OSHA activity number 314174350.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROFESSIONAL FACILITIES MANAGEMENT, INC.
- Site address
- 1000 EASTDALE MALL (EASTERN MALL)
- City
- MONTGOMERY
- State
- AL
- ZIP
- 36109
- Mailing
- 4164 TROY HWY, MONTGOMERY, AL 36116
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 22
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $4,500 · Current $3,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazardous chemical vapors from Freon R-22: a.In and around the compressor/refrigeration machinery room: On or about March 22, 2010 the employer exposed employees to the hazards of Freon R-22 chemically referred to as chlorodifluoromethane during emergency situations and leaks associated with the mechanical refrigeration system for the Ice Palace. b.In and around the compressor/refrigeration machinery room: On March 22, 2010 and at times prior to, employees were exposed to the hazards of Freon R-22 chemically referred to as chlorodifluoromethane during emergency situations by the employer not having installed a Freon R-22 monitoring system interlocked with a ventilation system that was adequate enough to exhaust air from the room in the event of a leak or rupture in such a manner as not to cause a nuisance or danger to employees. Among other methods, one feasible and acceptable abatement method to correct this hazard is to provide an adequate functional detection system that would actuate an alarm and mechanical ventilation at an exhaust rate sufficient to remove vapors out of the Mechanical Refrigeration Room in accordance with American Society of Heating Refrigeration and Air-Conditioning Engineers (ASHRAE) "Safety Code for Mechanical Refrigeration" #15.igeration"
Recent events (2)
- — I (S) $3000.00
- — Z (S) $4500.00
1910.120 Q01
- Issued
- Sep 20, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,250 · Current $1,350 Reduced
Recent events (2)
- — I (S) $1350.00
- — Z (S) $2250.00
1910.132 D01
- Issued
- Sep 20, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,250 · Current $1,350 Reduced
Recent events (2)
- — I (S) $1350.00
- — Z (S) $2250.00
1910.147 C07 IA
- Issued
- Sep 20, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $2,250 · Current $1,300 Reduced
Recent events (2)
- — I (S) $1300.00
- — Z (S) $2250.00
1910.1200 H01
- Issued
- Sep 20, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $4,500 · Current $3,000 Reduced
Recent events (2)
- — I (S) $3000.00
- — Z (S) $4500.00
1904.29 B01
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
1904.29 B01
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
1904.29 B01
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
1904.29 B02
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
1904.29 B02
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
1904.29 B02
- Issued
- Sep 20, 2010
- Abate by
- Oct 15, 2010
- Penalty
- Initial $900 · Current $500 Reduced
Recent events (2)
- — I (O) $500.00
- — Z (O) $900.00
More inspections at Professional Facilities Management, INC.
View Professional Facilities Management, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561790)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314174350.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.