DALLAS, TX ·
OSHA Inspection: PRISTINE WINDOW SERVICE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRISTINE WINDOW SERVICE, LLC in 1309 MAIN STREET, DALLAS, TX 75202 (NAICS 561790). OSHA activity number 314179102.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRISTINE WINDOW SERVICE, LLC
- Site address
- 1309 MAIN STREET
- City
- DALLAS
- State
- TX
- ZIP
- 75202
- Mailing
- P. O. BOX 2884, GRAPEVINE, TX 76099
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
- Penalty
- Initial $1,500 · Current $900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: On or about September 22, 2010, and at times prior thereto, on the South side of the Davis Building located at 1309 Main Street, Dallas, TX; at least two employees, who were washing windows while working from Sky Genie Seatboard Systems without vertical life lines attached to anchor points independent of the seatboard systems, were exposed to the hazard of falling as much as 252 feet to the lower level. Among other methods, feasible and acceptable means of abatement include but are not limited to: (1) Install roof support equipment and suspension devices for rope descent systems that meet the design and installation requirements of American National Standards Institute standard ANSI/IWCA I-14.1 "Window Cleaning Safety;" (2)Ensure that fall arrest system including vertical lines are independent of scaffold or suspension device support lines. (3)Ensure that independent anchorage points have been certified that they are capable of sustaining a 5000 pound minimum load, or a minimum 4 to 1 safety factor whichever is larger.
Recent events (2)
- · I (S) $900.00
- · Z (S) $1500.00
1910.135 A01
- Issued
- Nov 1, 2010
- Abate by
- Nov 9, 2010
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- · I (S) $360.00
- · Z (S) $600.00
More inspections in this industry (NAICS 561790)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314179102.