Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUOR ENTERPRISES

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of FLUOR ENTERPRISES in 1320 MCENTIRE, TRINIDAD, TX 75163 (NAICS 236210). OSHA activity number 314183369.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluor Enterprises — free Get an email when a new federal OSHA severe-injury report for Fluor Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
FLUOR ENTERPRISES
Site address
1320 MCENTIRE
City
TRINIDAD
State
TX
ZIP
75163
Mailing
9000 W. JEFFERSON 609/ BUILDING, DALLAS, TX 75211
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
SIC code (legacy)
1629
Employees
4
Ownership type
A
Industry flags
Manufacturing safety.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 27, 2011
Abate by
Jan 2, 2012
Penalty
Initial $7,000 · Current $7,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer
does not
furnish to each of their employees employment and a place of employment
which are free
from the recognized hazards of being struck-by and/or crushed-by falling
pipes/racks which
are causing or likely to cause death or serious physical harm to employees:
This violation occurred on or about June 30, 2011, where employees were
exposed to struck-
by and/or crushed-by hazards from a pipe storage rack that was not
anchored.
Among the feasible method to correct the hazard includes, but not limited
to: Follow
MH16:2008, ANSI-RMI Specification for Design, Testing and Utilization of
Industrial Steel
Storage Racks, Section 1.4.7, which specifies that all rack columns shall
be anchored with
anchor bolts capable of resisting forces by the horizontal and vertical
loads on the rack.
Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the
abatement date, the
employer must submit documentation describing the actions it  is taking to
ensure that
employees are  protected from struck by falling and/or collapsing pipe
racks.sing
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

1910.176 B

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 27, 2011
Abate by
Jan 2, 2012
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

View Fluor Enterprises's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314183369.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.