Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LAREDO TRANSIT MANAGEMENT INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LAREDO TRANSIT MANAGEMENT INC in 401 SCOTT STREET, LAREDO, TX 78040 (NAICS 488490). OSHA activity number 314197559.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Laredo Transit Management INC — free Get an email when a new federal OSHA severe-injury report for Laredo Transit Management INC is published. One employer, no account, unsubscribe in one click.
Site address
401 SCOTT STREET
City
LAREDO
State
TX
ZIP
78040
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488490
SIC code (legacy)
4173
Employees
165
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 20 instances 11 exposed
Issued
Jul 13, 2010
Abate by
Aug 6, 2010
Penalty
Initial $1,375 · Current $825 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing, or likely to cause, death or serious physical harm to
employees in that employees
were exposed to struck-by hazards:
Southwest area of the workplace, Unit #1 & #2 Compressed Natural Gas (CNG)
equipment pressure devices: On or about March 12, 2010, and other times
prior
thereto, pressure gauge devices installed at heights of 33 to 63 inches
above the
floor and used by employees to monitor CNG system pressures were not
maintained in proper operating condition, exposing employees to struck-by
hazards. The maintenance of the following pressure gauges was required by
Item
4-16, Maintenance of the NFPA 52 CNG Vehicular Fuel Systems Code:
a.Unit #1 Kimray Gas Regulator pressure gauge: gauge indicator needle was
detached from the gauge rotating shaft,
b.Unit #1 Compressor Oil Filter Inlet pressure gauge: gauge glass cover was
damaged,
c.Unit #1 Compressor Oil Filter Inlet pressure gauge: gauge pressure
indicator needle was missing,
d.Unit #1 Compressor Oil Filter Outlet pressure gauge: gauge glass cover
was damaged,
e.Unit #1 First Stage pressure gauge: gauge glass cover was damaged,
f.Unit #1 Third Stage pressure gauge: gauge glass cover was damaged,
g.Unit #1 Third Stage pressure gauge: liquid filled gauge was partially
empty of fluid,
h.Unit #1 Fourth Stage pressure gauge: gauge glass cover was damaged,
i.Unit #1 Fourth Stage pressure gauge: liquid filled gauge was partially
empty of fluid,
j.Unit #2 First Stage pressure gauge: gauge glass cover was damaged,
k.Unit #2 First Stage pressure gauge: liquid filled gauge was partially
empty
of fluid,
l.Unit #2 Fourth Stage pressure gauge: gauge glass cover was damaged,
m.Unit #2 Fourth Stage pressure gauge: liquid filled gauge was partially
empty of fluid,n.Unit #2 Kimray Gas Regulator pressure gauge: gauge
indicator needle was
detached from the gauge rotating shaft,
o.Unit #2 Compressor Oil Filter Inlet pressure gauge: gauge glass cover was
damaged,
p.Buffer Pressure Control gauge for the Fuel Pressure Control Panel: gauge
glass cover was damaged,
q.Buffer Pressure Control gauge for the Fuel Pressure Control Panel: gauge
contained a deformed indicator needle,
r.Compressor Discharge gauge for the Fuel Pressure Control Panel: gauge
indicator needle was detached from the gauge rotating shaft,
s.Vehicle Pressure gauge for the Fuel Pressure Control Panel: gauge glass
cover was damaged,
t.Vehicle Pressure gauge for the Fuel Pressure Control Panel: liquid filled
gauge was partially empty of fluid.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to replace all defective pressure gauges with manufacturer's
recommended replacement gauges.
Recent events (2)
  • — I (S) $825.00
  • — Z (S) $1375.00

1910.305 B02

Serious Gravity 01 1 instance 11 exposed
Issued
Jul 13, 2010
Abate by
Aug 6, 2010
Penalty
Initial $825 · Current $495 Reduced
Recent events (2)
  • — I (S) $495.00
  • — Z (S) $825.00

1904.29 A

Other-than-serious Gravity 00 3 instances 12 exposed
Issued
Jul 13, 2010
Abate by
Aug 6, 2010
Penalty
Initial $1,000 · Current $600 Reduced
Recent events (2)
  • — I (O) $600.00
  • — Z (O) $1000.00

1904.29 B02

Other-than-serious Gravity 00 2 instances 12 exposed
Issued
Jul 13, 2010
Abate by
Aug 6, 2010
Penalty
Initial $1,000 · Current $600 Reduced
Recent events (2)
  • — I (O) $600.00
  • — Z (O) $1000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314197559.