LAREDO, TX —
OSHA Inspection: LAREDO TRANSIT MANAGEMENT INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LAREDO TRANSIT MANAGEMENT INC in 401 SCOTT STREET, LAREDO, TX 78040 (NAICS 488490). OSHA activity number 314197559.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAREDO TRANSIT MANAGEMENT INC
- Site address
- 401 SCOTT STREET
- City
- LAREDO
- State
- TX
- ZIP
- 78040
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488490
- SIC code (legacy)
- 4173
- Employees
- 165
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 13, 2010
- Abate by
- Aug 6, 2010
- Penalty
- Initial $1,375 · Current $825 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to struck-by hazards: Southwest area of the workplace, Unit #1 & #2 Compressed Natural Gas (CNG) equipment pressure devices: On or about March 12, 2010, and other times prior thereto, pressure gauge devices installed at heights of 33 to 63 inches above the floor and used by employees to monitor CNG system pressures were not maintained in proper operating condition, exposing employees to struck-by hazards. The maintenance of the following pressure gauges was required by Item 4-16, Maintenance of the NFPA 52 CNG Vehicular Fuel Systems Code: a.Unit #1 Kimray Gas Regulator pressure gauge: gauge indicator needle was detached from the gauge rotating shaft, b.Unit #1 Compressor Oil Filter Inlet pressure gauge: gauge glass cover was damaged, c.Unit #1 Compressor Oil Filter Inlet pressure gauge: gauge pressure indicator needle was missing, d.Unit #1 Compressor Oil Filter Outlet pressure gauge: gauge glass cover was damaged, e.Unit #1 First Stage pressure gauge: gauge glass cover was damaged, f.Unit #1 Third Stage pressure gauge: gauge glass cover was damaged, g.Unit #1 Third Stage pressure gauge: liquid filled gauge was partially empty of fluid, h.Unit #1 Fourth Stage pressure gauge: gauge glass cover was damaged, i.Unit #1 Fourth Stage pressure gauge: liquid filled gauge was partially empty of fluid, j.Unit #2 First Stage pressure gauge: gauge glass cover was damaged, k.Unit #2 First Stage pressure gauge: liquid filled gauge was partially empty of fluid, l.Unit #2 Fourth Stage pressure gauge: gauge glass cover was damaged, m.Unit #2 Fourth Stage pressure gauge: liquid filled gauge was partially empty of fluid,n.Unit #2 Kimray Gas Regulator pressure gauge: gauge indicator needle was detached from the gauge rotating shaft, o.Unit #2 Compressor Oil Filter Inlet pressure gauge: gauge glass cover was damaged, p.Buffer Pressure Control gauge for the Fuel Pressure Control Panel: gauge glass cover was damaged, q.Buffer Pressure Control gauge for the Fuel Pressure Control Panel: gauge contained a deformed indicator needle, r.Compressor Discharge gauge for the Fuel Pressure Control Panel: gauge indicator needle was detached from the gauge rotating shaft, s.Vehicle Pressure gauge for the Fuel Pressure Control Panel: gauge glass cover was damaged, t.Vehicle Pressure gauge for the Fuel Pressure Control Panel: liquid filled gauge was partially empty of fluid. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace all defective pressure gauges with manufacturer's recommended replacement gauges.
Recent events (2)
- — I (S) $825.00
- — Z (S) $1375.00
1910.305 B02
- Issued
- Jul 13, 2010
- Abate by
- Aug 6, 2010
- Penalty
- Initial $825 · Current $495 Reduced
Recent events (2)
- — I (S) $495.00
- — Z (S) $825.00
1904.29 A
- Issued
- Jul 13, 2010
- Abate by
- Aug 6, 2010
- Penalty
- Initial $1,000 · Current $600 Reduced
Recent events (2)
- — I (O) $600.00
- — Z (O) $1000.00
1904.29 B02
- Issued
- Jul 13, 2010
- Abate by
- Aug 6, 2010
- Penalty
- Initial $1,000 · Current $600 Reduced
Recent events (2)
- — I (O) $600.00
- — Z (O) $1000.00