JEFFERSON, GA —
OSHA Inspection: DSM NUTRITIONAL PRODUCTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DSM NUTRITIONAL PRODUCTS, INC. in 495 JACKSON CONCOURSE, JEFFERSON, GA 30549 (NAICS 325412). OSHA activity number 314206806.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DSM NUTRITIONAL PRODUCTS, INC.
- Site address
- 495 JACKSON CONCOURSE
- City
- JEFFERSON
- State
- GA
- ZIP
- 30549
- Mailing
- P.O. BOX 220, PENDREGRASS, GA 30567
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- SIC code (legacy)
- 2834
- Employees
- 13
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 12, 2011
- Abate by
- Nov 11, 2011
- Penalty
- Initial $3,750 · Current $3,750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: On or about December 21, 2010,the employer unknowingly furnished employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm including severe burns to employees, in that employees were exposed to dust explosion, deflagration, or other fire hazards from dust collection system: DSM Nutritional Products, Inc, Jefferson, GA - In the production tower, employees working in areas served by the dust collector system were exposed to explosion, deflagration, or fire hazards due the lack of isolation devices. Among other methods, a feasible abatement method to correct this hazard is to follow the NFPA 654 Standard for The Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulates Solids, paragraph 7.1.4.1 and 7.1.5.1, which require isolation devices to be provided to prevent deflagration propagation between pieces of equipment connected by ductwork and from air-material separators (dust collectors) upstream to the work area. Isolation devices include but are not limited to chokes, rotary valves, and flame front diverters. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
More inspections at DSM Nutritional Products, INC.
View DSM Nutritional Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314206806.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.