COLLINGDALE, PA ·
OSHA Inspection: SCULLY WELDING SUPPLY CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SCULLY WELDING SUPPLY CORPORATION in 309 OAK STREET, COLLINGDALE, PA 19023 (NAICS 221210). OSHA activity number 314229949.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCULLY WELDING SUPPLY CORPORATION
- Site address
- 309 OAK STREET
- City
- COLLINGDALE
- State
- PA
- ZIP
- 19023
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221210
- SIC code (legacy)
- 4924
- Employees
- 22
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 21, 2010
- Abate by
- Jan 13, 2011
- Penalty
- Initial $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Scully Welding Supply Corporation/309 Oak Avenue - The employer did not provide formal training for his employee who was assigned to fill the liquid propane tanks that were identified in the size from six to twenty pounds. This has been identified in the 2008 National Fire Protection Association [NFPA] standard; Section 4.4.4. This was observed on September 3, 2010. b)Scully Welding Supply Corporation/309 Oak Avenue - The employer did not have a qualified or competent person evaluating the transfer of the liquid propane that was being transferring from the 18 and 30 thousand gallon tanks used to fill the 20 gallon cylinders. This has been identified in the 2008 National Fire Protection Administration [NFPA] standard; Section 7.2.1.2. The compliance officer was informed of this on September 2, 2010. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct these hazards is to comply with NFPA 58 gas code by developing and implementing operator training. A second acceptable method to correct this hazard is to ensure training is performed concerning supervision of the employee while operating the fill lines. NOTE: DOCUMENTATION OF ABATEMENT OF THIS CONDITION IS REQUIRED.
Recent events (2)
- · I (S)
- · Z (S) $3500.00
1910.37 E
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- · I (S) $3500.00
- · Z (S) $3500.00
1910.110 D03 III
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $3,500
Recent events (2)
- · I (S)
- · Z (S) $3500.00
1910.110 D03 V
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
1910.120 Q02 V
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $1,250 · Current $3,500
Recent events (2)
- · I (S) $3500.00
- · Z (S) $1250.00
1910.120 Q02 II
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $2,500
Recent events (2)
- · I (S)
- · Z (S) $2500.00
1910.120 Q02 IV
- Issued
- Dec 21, 2010
- Abate by
- Jan 13, 2011
- Penalty
- Initial $2,500
Recent events (2)
- · I (S)
- · Z (S) $2500.00
1910.120 Q02 VI
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $3,500
Recent events (2)
- · I (S)
- · Z (S) $3500.00
1910.120 Q06 IIA
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $1,250
Recent events (2)
- · I (S)
- · Z (S) $1250.00
1910.141 A05
- Issued
- Dec 21, 2010
- Abate by
- Dec 24, 2010
- Penalty
- Initial $750
Recent events (2)
- · I (O)
- · Z (O) $750.00
1910.307 C02 I
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $3,500 · Current $4,500
Recent events (2)
- · I (S) $4500.00
- · Z (S) $3500.00
1910.1200 E01
- Issued
- Dec 21, 2010
- Abate by
- Jan 23, 2011
- Penalty
- Initial $1,250 · Current $3,500
Recent events (2)
- · I (O) $3500.00
- · Z (O) $1250.00
More inspections at Scully Welding Supply Corporation
View Scully Welding Supply Corporation's full OSHA safety record →
More inspections in this industry (NAICS 221210)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314229949.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.