PHILADELPHIA, PA —
OSHA Inspection: MRS. RESSLER'S FOOD PRODUCTS CO.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MRS. RESSLER'S FOOD PRODUCTS CO. in 5501 TABOR AVE., PHILADELPHIA, PA 19120 (NAICS 311612). OSHA activity number 314233693.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MRS. RESSLER'S FOOD PRODUCTS CO.
- Site address
- 5501 TABOR AVE.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19120
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- SIC code (legacy)
- 2013
- Employees
- 90
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 6, 2011
- Abate by
- Jul 24, 2011
- Penalty
- Initial $4,900 · Current $4,000 Reduced
0170
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an uncontrolled release of anhydrous ammonia: a) Mrs. Ressler's Food Products Co. - Adjacent to the compressor or gas mixing room employees were operating the ovens and were exposed to a release of anhydrous 20 feet of the ammonia refrigeration vessels in the compressor/mixing room. This shall be in accordance with ANSI/IIAR 2-1999 Section 13.1.1.6 of the standard. 3.The employer did not have the voids/holes in the walls of the compressor/mixing room tightly sealed. These voids were from pipes which had previously penetrated the wall. This shall be in accordance with ANSI/IIAR 2-1999 Section 13.3.1.9 of the standard. NOTE: DOCUMENTATION OF ABATEMENT OF THESE CONDITIONS IS REQUIRED.
Recent events (2)
- — I (S) $4000.00
- — Z (S) $4900.00
1910.151 C
- Issued
- Jul 6, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $4,410 · Current $4,000 Reduced
0170
Recent events (2)
- — I (S) $4000.00
- — Z (S) $4410.00
1910.157 E03
- Issued
- Jul 6, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $3,150
0170
Recent events (2)
- — I (O)
- — Z (S) $3150.00
1910.303 B08 IV
- Issued
- Jul 6, 2011
- Abate by
- Jul 11, 2011
- Penalty
- Initial $2,100
0170
Recent events (2)
- — I (O)
- — Z (O) $2100.00
1910.22 A02
- Issued
- Jul 6, 2011
- Abate by
- Jul 11, 2011
0170
Recent events (2)
- — I (O)
- — Z (O)
1910.120 E08
- Issued
- Jul 6, 2011
- Abate by
- Aug 8, 2011
0170
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 311612)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314233693.