YORK, PA —
OSHA Inspection: WAYNECO, INCORPORATED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of WAYNECO, INCORPORATED in 800 HANOVER ROAD, YORK, PA 17408 (NAICS 337110). OSHA activity number 314244757.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAYNECO, INCORPORATED
- Site address
- 800 HANOVER ROAD
- City
- YORK
- State
- PA
- ZIP
- 17408
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 30
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 7, 2011
- Abate by
- Jun 9, 2012
- Penalty
- Initial $2,380 · Current $1,785 Reduced
E200W103
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn injuries from the hazard of fire and explosion of wood dust from the lack of isolation devices and bonding and grounding equipment: (a)Wayneco, Incorporated - The fine sanding Scientific dust collector unit was not equipped with isolation devices to prevent fires and deflagrations from propagating from the dust collector back through the inlet ductwork to the woodworking equipment, or through the ductwork recycling exhausted air back into the building, on or about March 31, 2011. (b)Wayneco, Incorporated - The main Pneumafil dust collector unit was not equipped with isolation devices to prevent fires and deflagrations from propagating from the dust collector back through the inlet ductwork to the woodworking equipment, or through the ductwork recycling exhausted air back into the building, on or about March 31, 2011. (c)Wayneco, Incorporated - The relay system Scientific dust collector unit was not equipped with isolation devices to prevent fires and deflagrations from propagating from the dust collector back through the inlet ductwork to the woodworking equipment, or through the ductwork recycling exhausted air back into the building, on or about March 31, 2011. (d)Wayneco, Incorporated - The ductwork was not bonded and grounded for woodworking equipment, such as the table saw and automated belt sander, on or about March 31, 2011. ABATEMENT NOTE: Among other methods, one feasible and acceptable method to correct these hazards includes following the National Fire Protection Association (NFPA) 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, 2007 Edition, including, but not limited to: Provide permanent grounding and bonding of production equipment to control the accumulation of static electric charge (NFPA 664, Chapter 7, Section 7.9.2); Isolate conveying systems with fire and deflagration hazards to prevent propagation of fire and deflagration both upstream and downstream into occupied areas or other critical process equipment (NFPA 664, Chapter 8, Section 8.2.4.1). Examples of isolation methods include mechanical isolation (such as rotary airlock valves), chemical isolation (discharge of a chemical extinguishing agent into interconnecting pipe or duct), and flame front diverters (such as backblast dampers and high-speed abort gates). NFPA 664, Chapter 8, Section 8.2.2.2.1.8 states that ductwork shall be bonded and grounded in accordance with 7.9.2(1) which states that where equipment is subject to the accumulation of static charge, the accumulation of static electric charge shall be controlled by one of the following: (1) Permanent grounding and bonding of production equipment. All proposed control measures shall be approved for each particular use by a competentengineer or other technically qualified person. (Ninety (90) day progress reports are required during the abatement period.) *STEP 1 Submit to the Area Director a written, detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposure to hazardous substances referenced in this citation: 1.Evaluation of engineering/administrative control options. 2.Selection of optimum control methods and completion of design. 3.Procurement, installation and operation of selected control measures; and 4.Acceptance or modification/redesign of controls. *STEP 2 Abatement shall have been completed by the implementation of feasible engineering upon verification of their effectiveness in achieving compliance. Date by Which Violation Must be Abated:STEP - 1 - 09/08/11 Date by Which Violation Must be Abated:STEP - 2 - 06/09/12 VERIFICATION REQUIRED
Recent events (2)
- — I (S) $1785.00
- — Z (S) $2380.00
1910.22 A02
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
- Penalty
- Initial $1,785 · Current $1,338 Reduced
E200W103
Recent events (2)
- — I (S) $1337.50
- — Z (S) $1785.00
1910.157 G02
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
E200W103
1910.1200 H01
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
E200W103
1910.147 C04 IIB
- Issued
- Jun 7, 2011
- Abate by
- Aug 9, 2011
- Penalty
- Initial $1,785 · Current $1,338 Reduced
Recent events (2)
- — I (S) $1337.50
- — Z (S) $1785.00
1910.147 C05 I
- Issued
- Jun 7, 2011
- Abate by
- Jun 10, 2011
1910.147 C06 II
- Issued
- Jun 7, 2011
- Abate by
- Aug 9, 2011
1910.147 C07 IIIB
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
1910.147 C07 IV
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
1910.107 B05 I
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
E109259000400440
1910.178 L06
- Issued
- Jun 7, 2011
- Abate by
- Jul 10, 2011
More inspections at Wayneco, Incorporated
View Wayneco, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314244757.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.