NAPLES, FL ·
OSHA Inspection: ALL WEATHER HURRICANE SHUTTERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALL WEATHER HURRICANE SHUTTERS, INC. in 1224 INDUSTRIAL BLVD, NAPLES, FL 34104 (NAICS 332321). OSHA activity number 314267238.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL WEATHER HURRICANE SHUTTERS, INC.
- Site address
- 1224 INDUSTRIAL BLVD
- City
- NAPLES
- State
- FL
- ZIP
- 34104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- SIC code (legacy)
- 3442
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 13, 2010
- Abate by
- Dec 27, 2010
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On or about 11/11/2010, All Weather Hurricane Shutters, Naples, FL. a.Employees were exposed to caught by hazards when used a drill press (Enco Model 125-1171) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. b.Employees were exposed to caught by hazards when used a drill press (Model 7931288152) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. c.Employees were exposed to caught by hazards when used a drill press (Enco Model 125-1170, Serial #07360) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. d.Employees were exposed to caught by hazards when used a drill press (Enco Model 125-1170, Serial #08517) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. e.An employee was exposed to caught by hazards when used a radial saw (Serial #18983) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. f.Employees were exposed to caught by hazards when used a bandsaw (Craftsman Professional, Model 119-224010) that lacked a magnetic restart to prevent automatic reenergization upon restoration of power. g.An employee was exposed to caught by hazards when used a radial saw (Serial #18983) that did not return automatically to the starting position when released by the operator. h.An employee was exposed to caught by hazards when used a radial saw (Serial #18983) that was not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations. Note:Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively. Among the feasible and useful methods to correct the hazard in instances a through f is to prohibit the use of the machines until magnetic restart switches are provided. Among the feasible and useful methods to correct the hazard in instance g is to provide the machine with a mechanism to ensure automatic return when released, or raise the height of the table in the front to ensure automatic return by gravity. Among the feasible and useful methods to correct the hazard in instance h are providing an adjustable stop or extending the length of the table.
Recent events (2)
- · I (S) $1530.00
- · Z (S) $2550.00
1910.212 A01
- Issued
- Dec 13, 2010
- Abate by
- Dec 27, 2010
- Penalty
- Initial $2,550 · Current $1,530 Reduced
Recent events (2)
- · I (S) $1530.00
- · Z (S) $2550.00
1910.212 B
- Issued
- Dec 13, 2010
- Abate by
- Dec 16, 2010
- Penalty
- Initial $1,300 · Current $780 Reduced
Recent events (2)
- · I (S) $780.00
- · Z (S) $1300.00
1910.219 C02 I
- Issued
- Dec 13, 2010
- Abate by
- Dec 27, 2010
- Penalty
- Initial $1,530 · Current $918 Reduced
Recent events (2)
- · I (S) $918.00
- · Z (S) $1530.00
More inspections in this industry (NAICS 332321)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314267238.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.