LEWISVILLE, TX —
OSHA Inspection: CENTRAL CONCRETE PUMPING
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of CENTRAL CONCRETE PUMPING in 940 LAKESIDE CIRCLE, LEWISVILLE, TX 75057 (NAICS 238110). OSHA activity number 314274358.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRAL CONCRETE PUMPING
- Site address
- 940 LAKESIDE CIRCLE
- City
- LEWISVILLE
- State
- TX
- ZIP
- 75057
- Mailing
- 7540 CONFEDERATE PARK RD., FT. WORTH, TX 76108
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- SIC code (legacy)
- 1771
- Employees
- 18
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 4, 2010
- Abate by
- Nov 30, 2010
- Penalty
- Initial $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck by the collapsing boom pump due to failure to conduct recommended maintenance This violation was last known to occur on 6/24/10. Employees and subcontractor' employees were exposed to the boom of the Schwing America pump collapsing on them because proper maintenance checks are not performed. Among other methods, one feasible and acceptable method to abate this hazard is to make a visual inspection of the structural support system on a daily to monthly basis by a designated person in accordance with manufacturer's recommendation in the operator's manual. Pursuant to 29 CFR 1903.19, the employer must submit an abatement plan within 25 days describing the actions it is taking to ensure compliance, including a description of how these steps protect employees from being struck by collapsing boom pumps.sing
Recent events (2)
- — F (S)
- — Z (S) $1500.00
More inspections in this industry (NAICS 238110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314274358.