CORTLAND, NY ·
OSHA Inspection: CORTLAND CHRYSLER DODGE JEEP, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORTLAND CHRYSLER DODGE JEEP, INC. in 3878 WEST ROAD, CORTLAND, NY 13045 (NAICS 441110). OSHA activity number 314348046.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORTLAND CHRYSLER DODGE JEEP, INC.
- Site address
- 3878 WEST ROAD
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- SIC code (legacy)
- 5511
- Employees
- 23
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 18, 2010
- Abate by
- Dec 1, 2010
- Penalty
- Initial $4,200 · Current $1,080 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY A LOAD: a)Service Department, on or about 11/3/10: The following Challenger vehicle lifts used were not maintained in safe operating condition: 2)Challenger, Model 24012AR, Serial No. 030300000003076, had the rear front safety rod bent and warning labels were missing. Among other methods, one feasible and acceptable abatement method to correct these hazards is to conduct inspections of the lifts as recommended by the manufacturer to ensure safe operation and to remove damaged lifts from service until rendered safe for use. Also, follow the requirements of ANSI/ALI ALOIM-1994, Safety Requirements for Operation, Inspection and Maintenance, Section 5, Periodic Qualified Inspection and Section 6, Maintenance. b)Service Department, on or about 11/04/10: Jacks used to support vehicles for servicing purposes were not marked with load capacity ratings and had never been inspected. Among other methods, one feasible and acceptable abatement method to correct these hazards is to determine the load rating of each jack and mark them accordingly. Also, follow the inspection requirements of ANSI B30.1- 1975 Jacks, Chapter 1-2 Inspection, Testing and Maintenance. Abatement certification must be submitted for this item.
Recent events (2)
- · I (S) $1080.00
- · Z (S) $4200.00
1910.147 C04 I
- Issued
- Nov 18, 2010
- Abate by
- Dec 6, 2010
- Penalty
- Initial $2,400 · Current $1,080 Reduced
Recent events (2)
- · I (S) $1080.00
- · Z (S) $2400.00
1910.147 C07 I
- Issued
- Nov 18, 2010
- Abate by
- Dec 6, 2010
Recent events (2)
- · I (S)
- · Z (O)
1910.303 B01 VIII
- Issued
- Nov 18, 2010
- Abate by
- Dec 6, 2010
- Penalty
- Initial $1,800
Recent events (2)
- · I (O)
- · Z (S) $1800.00
More inspections at Cortland Chrysler Dodge Jeep, INC.
View Cortland Chrysler Dodge Jeep, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 314348046.