Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CABLE TEL SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CABLE TEL SERVICES, INC. in 4710 MOFFETT RD., MOBILE, AL 36618 (NAICS 238210). OSHA activity number 314354705.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cable TEL Services, INC. — free Get an email when a new federal OSHA severe-injury report for Cable TEL Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4710 MOFFETT RD.
City
MOBILE
State
AL
ZIP
36618
Mailing
1756 THOMAS RD., MEMPHIS, TN 38134
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
5
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 13, 2010
Abate by
Sep 30, 2010
Penalty
Initial $3,500 · Current $3,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to flash fires, explosions and asphyxiation hazards due to a
hazardous atmosphere
while working in a confined space:
a)Manhole Number ME-1: On or about April 29, 2010, the employees were
exposed to flash fires, explosion hazards and asphyxiation hazards while
working
inside a manhole. Natural gas had accumulated inside the manhole and the
employer did not provide the employees with a meter to test the atmosphere
prior
to entering and did not have a blower motor to ventilate the manhole prior
to
working inside.
Among others, one feasible abatement method is to follow the American
National
Standard Institute (ANSI), Standard Z117.1-2009, Safety Requirements for
Confined Spaces, including the identification of hazards within a confined
space
(required in Section 3), control or elimination of atmospheric hazards
prior to
entry into the space (required in Section 5), atmospheric testing when
necessary
(required in Section 6), retrieval equipment (required in Section 12), and
emergency rescue provisions (required in Section 14).

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 13, 2010
Abate by
Sep 23, 2010
Penalty
Initial $3,500 · Current $3,500

View Cable TEL Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314354705.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.