CLEVELAND, OH —
OSHA Inspection: NATIONAL OFFICE SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL OFFICE SERVICES, INC. in 15665 BROOKPARK ROAD, CLEVELAND, OH 44142 (NAICS 337214). OSHA activity number 314382235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL OFFICE SERVICES, INC.
- Site address
- 15665 BROOKPARK ROAD
- City
- CLEVELAND
- State
- OH
- ZIP
- 44142
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337214
- SIC code (legacy)
- 2522
- Employees
- 78
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 14, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $700 · Current $420 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burns from the potential dust explosion, deflagration and fire hazards caused by the improper design, and maintenance of dust collection system. Enclosureless (10 horse power) dust collector was inside the building and did not have adequate safeguards to prevent/mitigate a dust explosion. a) The fan was a potential ignition source because it was not totally enclosed. b) The dust collector was not at least 20 feet away from personnel and other equipment used by personnel. c) The dust collector was not bonded and grounded. ABATEMENT NOTE:Among other methods, one feasible and acceptable abatement method to correct these hazards is to have a qualified engineer inspect the cyclone the dust collection system to ensure that it is designed and installed in accordance with National Fire Protection Association (NFPA) 664-2007, section 8.2.2.5.1.4, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Abatement include: *Move the cyclone dust collector 20 feet away from employees,means of egress, and other occupied areas. *Bond and ground the dust collection system by method as listed in NFPA 664-2007, paragraph 7.6.2.aph
Recent events (2)
- — I (S) $420.00
- — Z (S) $700.00
1910.212 A01
- Issued
- Jul 14, 2010
- Abate by
- Jul 22, 2010
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
More inspections at National Office Services, INC.
View National Office Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337214)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314382235.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.