DANIELSON, CT —
OSHA Inspection: DELTA RUBBER COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELTA RUBBER COMPANY in 39 WAUREGAN ROAD, DANIELSON, CT 06239 (NAICS 326299). OSHA activity number 314406638.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELTA RUBBER COMPANY
- Site address
- 39 WAUREGAN ROAD
- City
- DANIELSON
- State
- CT
- ZIP
- 06239
- Mailing
- P.O. BOX 300, DANIELSON, CT 06239
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- SIC code (legacy)
- 3069
- Employees
- 98
- Ownership type
- A
Citations
20 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 3, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $2,625 · Current $1,313 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to potential fire and explosion hazards: Building B, Mold Maintenance Area: The Maxi-Blast Pressure Blast System Model MB 4B- 4BP-DC200 consisting of a blast cabinet and dust collector. A.Blast Cabinet: Employees were exposed to fire and/or explosion hazards because the Maxi-Blast Pressure Blast System's blast cabinet (where manufacturing molds were blast cleaned by plastic beads in a process that generates combustible plastic dust) produced sparks when the blast nozzle was in use. There was incomplete grounding within the blast cabinet, which enhanced the fire/explosion hazards. In addition, the blast nozzle could operate even when the dust collector was off, which permitted the accumulation of combustible dust in the blast cabinet. Among other methods, one feasible and acceptable abatement method to correct this hazard is: to eliminate ignition sources in the cabinet, to ensure that the blast cabinet is completely grounded, and to interlock the blast nozzle with the dust collector to ensure that the dust is properly evacuated from the blast cabinet. Refer to National Fire Protection Association (NFPA) 654 Standard for the Prevention of Fire and Dust Explosions of Combustible Particulate Solids for further details on feasible abatement methods. B.Dust Collector: Employees were exposed to fire and/or explosion hazards because the dust collector component of the Maxi-Blast Pressure Blast System (which generates combustible plastic dust as it blast-cleans the manufacturing molds) was located inside the building near the blast cabinet in the work area. The dust collector was not equipped with systems for fire/explosion prevention, suppression, venting and/or isolation, to prevent or limit the spread of a potential dust fire/explosion into the general work area and/or back into the blast cabinet. Also, the dust collector was joined to the blast cabinet's exhaust duct with a plastic hose and it was equipped with sateen cotton collection bags, both of which are combustible and both of which lack anti-static properties needed to minimize ignition possibilities. In addition, the dust collector recycled exhaust air back into the work area such that a fire/explosion in the collector could spread inside the building. Among other methods, one feasible and acceptable method to correct this hazard is to: -locate the dust collector outside of the building or equip it with protective devices, such as fire detection, explosion suppression, explosion isolation, and explosion venting; -isolate the dust collector from the blast cabinet to eliminate the propagation of fire/explosion from one to the other; -install metal ducts (noncombustible) instead of plastic hose;-ensure that all components are conductive and completely bonded and grounded. Refer to National Fire Protection Association (NFPA) 654 Standard for the Prevention of Fire and Dust Explosions of Combustible Particulate Solids for further details on feasible abatement methods.
Recent events (2)
- — I (S) $1312.50
- — Z (S) $2625.00
1910.107 B09
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $2,625 · Current $1,313 Reduced
Recent events (2)
- — I (S) $1312.50
- — Z (S) $2625.00
1910.107 C04
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.107 C09 I
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.124 B04
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $2,625 · Current $1,313 Reduced
Recent events (2)
- — I (S) $1312.50
- — Z (S) $2625.00
1910.124 C03
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.125 E01 I
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.124 J02 I
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $1,575 · Current $788 Reduced
Recent events (2)
- — I (S) $787.50
- — Z (S) $1575.00
1910.124 J03
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.138 B
- Issued
- Feb 3, 2012
- Abate by
- Aug 16, 2011
- Penalty
- Initial $1,785 · Current $893 Reduced
Recent events (2)
- — I (S) $892.50
- — Z (S) $1785.00
1910.147 C04 I
- Issued
- Feb 3, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
Recent events (2)
- — I (S) $892.50
- — Z (S) $1785.00
1910.303 B02
- Issued
- Feb 3, 2012
- Abate by
- Sep 14, 2011
- Penalty
- Initial $1,785 · Current $893 Reduced
Recent events (2)
- — I (S) $892.50
- — Z (S) $1785.00
1910.303 G01 IA
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $2,625 · Current $1,313 Reduced
Recent events (2)
- — I (S) $1312.50
- — Z (S) $2625.00
1910.303 G01 IC
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.303 G01 II
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.332 B01
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $2,625 · Current $1,313 Reduced
Recent events (2)
- — I (S) $1312.50
- — Z (S) $2625.00
1910.333 A02
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.335 A01 I
- Issued
- Feb 3, 2012
- Abate by
- Mar 21, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.110 B06 VI
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (O)
- — Z (O)
1910.334 A02 II
- Issued
- Feb 3, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Delta Rubber Company
View Delta Rubber Company's full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314406638.