ONTARIO, OR —
OSHA Inspection: SELECT ONION LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SELECT ONION LLC in 602 STANTON BLVD, ONTARIO, OR 97914 (NAICS 115114). OSHA activity number 314521733.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SELECT ONION LLC
- Site address
- 602 STANTON BLVD
- City
- ONTARIO
- State
- OR
- ZIP
- 97914
- Mailing
- PO BOX 1010, ONTARIO, OR 97914
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115114
- SIC code (legacy)
- 0723
- Employees
- 250
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
42 citations on file for this inspection.
1910.119 C02
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $1,500
0170
Recent events (2)
- — L (S)
- — Z (S) $1500.00
1910.119 C03
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
0170
Recent events (2)
- — L (S)
- — Z (S)
1910.119 C01
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
0170
Recent events (2)
- — L (S)
- — Z (S)
1910.119 D01
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $2,500
0170
Recent events (2)
- — L (S)
- — Z (S) $2500.00
1910.119 D02 I
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S) $1700.00
- — P (S)
- — Z (S)
1910.119 D03 I
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 D03 II
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $5,000 · Current $5,000
0170
Recent events (3)
- — L (S) $5000.00
- — P (S) $5000.00
- — Z (S) $5000.00
410
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
General-duty citation text
ORS 654.010: The employer did not furnish a place of employment which was safe and healthful for employees, did not furnish and use such devices and safeguards, and did not adopt and use such practices, means, methods, operations and processes as was reasonably necessary to render such employment and places of employment safe and healthful, and did not do every other thing reasonably necessary to protect the life, safety, and health of the employees: a) As of the date of the inspection, the employer failed to furnish reasonably necessary devices and safeguards or did not adopt and use such practices, means, methods, operations and processes as stipulated in industry standards such as, but not limited to, the American National Standards Institute/American Society of Heating, Refrigerating and Air Conditioning Engineers (ANSI/ASHRAE) and the International Institute of Ammonia Refrigeration (IIAR). As observed by one or more of the following in the 2008 anhydrous ammonia refrigeration system: i) The presence of the air compressor system (with pump intake) in the 2008 ammonia engine room permits the passage of escaping refrigerant to other parts of the building including, but not limited to, the welding shop. A feasible method to address this would be to remove the compressed air system from the anhydrous ammonia engine room. (See: ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 8.11.2 - General Requirements; See IIAR bulletin 2-2008: Equipment, Design and Installation of Closed Circuit Ammonia Refrigerating System, Section 13.2.3.10 - Ventilation) ii) The condensers servicing the 2008 ammonia refrigeration system did not have safe access to provide for inspection, service and emergency shut down. The access ladder for the units did not reach the ground level, thus requiring employees to jump 5 feet to access first rung of the ladder. The condenser units did not have catwalks to provide safe access to all sides of the units; thus, employees had to use portable ladders or straddle I-beams to access portions of the units. A feasible method to address this would be to install work platforms or catwalks with compliant stairs or fixed ladders in all areas where inspection and maintenance are required. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 8.3 - Safe Access or section 9.12.1 & 9.12.2 - Service Provisions) iii) The electrical systems installed in the 2008 ammonia engine room did not comply with the requirements of Class 1 - Division 2 of the National Electrical Code for hazardous locations. A feasible method to address this would be to evaluate the current ventilation system and system safety interlocks to verify if the system qualifies for the listed exemptions to this requirement. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 8.12(g) - Machinery Room Special Requirements See IIAR Bulletin 2-2008: Equipment, Design and Installation of Closed Circuit Ammonia Refrigerating System, Section 13.2.1.2 - Ventilation) iv) The observance of numerous isolation valves, servicing equipment in the 2008 ammonia system without any identification information. A feasible method to address this would be to install identification tags on all isolation valves. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 9.12.6 - service provisions) v) Lack of signage indicating the name and address of the installer, the refrigerant number and the maximum intended refrigerant load, the lubricant identity and amount, and the field test pressure applied. A feasible method to address this would be to install a permanent sign with the above-listed elements in the engine room. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 11.2 - General Requirements; See IIAR Bulletin 112: Ammonia Machinery Room Design, Section 4.3(f) - Mechanical) vi) The lack of drain plugs/stop valves on oil drain ports in the 2008 ammonia engine room. A feasible method to address this would be to install drain plugs on all oil drain ports. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 11.6.1 - General Requirements) vii) The lack of a ventilation system design, for the 2008 ammonia refrigeration system, to ensure that the current system is capable of providing the required airflow as required by the ASHRAE Standard. A feasible method to address this would be to develop a ventilation system design plan and verify that the current system is capable of delivering the required air flow during normal and emergency operations. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 8.11.5 - Machinery Room General Requirements; See IIAR Bulletin 2-2008: Equipment, Design and Installation of Closed Circuit Ammonia Refrigerating Systems, Section 13.2.3.3 - Ventilation) viii) The lack of a pressure relief design, for the 2008 ammonia refrigeration system, to ensure that the safety relief valves currently installed in the system are properly sized to adequately protect the system. A feasible method to address this would be to develop a pressure relief design plan to verify that the currently installed pressure relief valves and associated discharged piping are properly sized to adequately protect the equipment or piping systems. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 9.7.5 Pressure Relief Protection; See IIAR Bulletin 2-2008: Equipment, Design and Installation of Closed Circuit Ammonia Refrigerating Systems, Section 11.2.7 and 11.2.9 - Pressure Vessel Protection) ix) The lack of a schematic drawing or panel giving directions for the operation of the system at a location that is convenient to the operators. The lack of written emergency shutdown procedures (including shutdown instructions, contact information for obtaining system services, and the contact information for all required notifications in the event of a reportable incident) posted outside of the engine room and immediately adjacent to each door. A feasible method to address this would be to develop the schematic drawing with the above-listed information and post it immediately adjacent to each engine room door. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 11.7 - Responsibility for Operation and Emergency Shutdown) x) The lack of adequate safeguarding for piping on the roof servicing the 2008 ammonia system. Currently, employees have to cross over roof piping to inspect and access other portions of the system. There is no pedestrian bridge or catwalk over the piping system. This leaves the piping system vulnerable to physical damage due to employees "walking" crawling on pipes. There were numerous sections of the pipe support system that were subject to ice migration between the pipe and the protective sleeve. There was evidence that the expansion of the ice has compressed the pipe insulation system. A feasible method to address this would be to install a compliant pedestrian crossing ramp over the piping systems and to protect the pipe supports from ice migration. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 11.1 - General Requirements)
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 E01
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $2,500 · Current $2,500
0170
Recent events (3)
- — L (S) $2500.00
- — P (S) $2500.00
- — Z (S) $2500.00
1910.119 F01 I
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500 · Current $1,500
0170
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $1500.00
1910.119 G01 I
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $2,500 · Current $2,500
0170
Recent events (3)
- — L (S) $2500.00
- — P (S) $2500.00
- — Z (S) $2500.00
1910.1200 H03 III
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 H02 I
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500
0170
Recent events (3)
- — L (O)
- — P (O)
- — Z (S) $1500.00
1910.119 I01
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $1,500
0170
Recent events (2)
- — L (S)
- — Z (S) $1500.00
1910.119 J02
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $5,000 · Current $2,500 Reduced
0170
Recent events (3)
- — L (S) $2500.00
- — P (S) $2500.00
- — Z (S) $5000.00
1910.119 J03
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 J04 III
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
410
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
0170
General-duty citation text
ORS 654.010: The employer did not furnish a place of employment which was safe and healthful for employees, did not furnish and use such devices and safeguards, and did not adopt and use such practices, means, methods, operations and processes as was reasonably necessary to render such employment and places of employment safe and healthful, and did not do every other thing reasonably necessary to protect the life, safety, and health of the employees: a) As of the date of the inspection, the employer failed to furnish reasonably necessary devices and safeguards or did not adopt and use practices, means, methods, operations, and processes as stipulated in industry standards such as, but not limited to, the American National Standards Institute/American Society Heating, Refrigerating and Air Conditioning Engineers (ANSI/ASHRAE) and the International Institute of Ammonia Refrigeration (IIAR). As shown by one or more of the following: i) The employer failed to maintain the ammonia detection system, installed in the 2008 ammonia engine room, according to the manufacturer's recommendations and the industry standards. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration Systems, Section 11.6.3 - Periodic Tests) ii) The employer failed to maintain isolation valves installed in the 2008 ammonia system as stated by the industry standards of ANSI/ASHRAE and IIAR. (See ANSI/ASHRAE Standard 15 - 2001 Safety Systems for Refrigeration System, Section 11.6; See International Institute of Ammonia Refrigeration (IIAR) Bulletin 110 Revised 03/02: Guidelines for Start-up, Inspection and Maintenance of Ammonia Mechanical Refrigerating Systems, Section 6.6.1 Shut off valves) iii) The employer failed to maintain the condensers servicing the 2008 refrigeration system according to the manufacturer's recommendations. (See Evapco Manufacturer's Manual and Bulletin 112AC: Maintenance Instructions Closed Circuit Coolers and Evaporative Condensers) iv) The employer failed to maintain safeguards such as equipment manuals, current piping and instrument drawings, preventative maintenance schedules, and energy isolation procedures for the 2008 ammonia system. (See International Institute of Ammonia Refrigeration (IIAR) Bulletin 110, revised 03/2002, The Start-up, Inspection and Maintenance of Ammonia Mechanical Refrigeration Systems, Section 4.0 Records)
Recent events (2)
- — L (S)
- — Z (S)
1910.119 J05
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 J04 IV
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.119 K01
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500 · Current $1,000 Reduced
0170
Recent events (3)
- — L (S) $1000.00
- — P (S) $1000.00
- — Z (S) $1500.00
1910.119 L01
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500 · Current $1,500
0170
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $1500.00
1910.119 M01
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $2,500 · Current $2,500
0170
Recent events (3)
- — L (S) $2500.00
- — P (S) $2500.00
- — Z (S) $2500.00
1910.119 N
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500 · Current $1,000 Reduced
0170
Recent events (3)
- — L (S) $1000.00
- — P (S) $1000.00
- — Z (S) $1500.00
1910.120 Q01
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.146 C01
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
01700560
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $2500.00
1910.146 C04
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $1,500 · Current $1,000 Reduced
Recent events (3)
- — L (S) $1000.00
- — P (S) $1000.00
- — Z (S) $1500.00
1910.146 D03
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
0170
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $2500.00
1910.146 D04
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
0170
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.146 D09
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
Recent events (3)
- — L (S)
- — P (S)
- — Z (S)
1910.146 G01
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $2500.00
1910.134 C01
- Issued
- May 19, 2011
- Abate by
- Jun 5, 2011
- Penalty
- Initial $2,500 · Current $1,500 Reduced
0170
Recent events (2)
- — L (S) $1500.00
- — Z (S) $2500.00
1910.134 E01
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
0170
Recent events (2)
- — L (S)
- — Z (S)
1910.134 F02
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
0170
Recent events (2)
- — L (S)
- — Z (S)
1910.134 K03
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
Recent events (2)
- — L (S)
- — Z (S)
1910.133 A01
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $500 · Current $500
0170
Recent events (2)
- — L (S) $500.00
- — Z (S) $500.00
1910.138 A
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $500 · Current $500
888088708310
Recent events (2)
- — L (S) $500.00
- — Z (S) $500.00
1910.135 B01 I
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $500 · Current $500
Recent events (2)
- — L (S) $500.00
- — Z (S) $500.00
702016105 A
- Issued
- May 19, 2011
- Abate by
- Sep 30, 2011
- Penalty
- Initial $1,000 · Current $1,000
0170
Recent events (3)
- — L (S) $1000.00
- — P (S) $1000.00
- — Z (S) $1000.00
702037804 A
- Issued
- May 19, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,500 · Current $1,500
01701803
Recent events (3)
- — L (S) $1500.00
- — P (S) $1500.00
- — Z (S) $1500.00
702008105
- Issued
- May 19, 2011
- Abate by
- Jun 19, 2011
- Penalty
- Initial $300 · Current $300
0560
Recent events (2)
- — L (S) $300.00
- — Z (S) $300.00
1910.110 C08
- Issued
- May 19, 2011
- Abate by
- Jun 5, 2011
- Penalty
- Initial $300 · Current $300
2150
Recent events (2)
- — L (S) $300.00
- — Z (S) $300.00
More inspections at Select Onion LLC
View Select Onion LLC's full OSHA safety record →
More inspections in this industry (NAICS 115114)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314521733.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.