Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: COSTCO WHOLESALE CORPORATION #356

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of COSTCO WHOLESALE CORPORATION #356 in 1205 NORTH MEMORIAL PKWY, HUNTSVILLE, AL 35801 (NAICS 452910). OSHA activity number 314557430.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Costco Wholesale Corporation #356 for free Get an email when a new federal OSHA severe-injury report for Costco Wholesale Corporation #356 is published. One employer, no account, unsubscribe in one click.
Site address
1205 NORTH MEMORIAL PKWY
City
HUNTSVILLE
State
AL
ZIP
35801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452910
SIC code (legacy)
5399
Employees
140
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 05 1 instance 25 exposed
Issued
Dec 1, 2010
Abate by
Dec 27, 2010
Penalty
Initial $6,000 · Current $6,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees a place of employment which were free
from recognized
hazards that were causing or likely to cause death or serious physical
harm to his employees in
that employees were exposed to hazardous chemical vapor from Freon R-22:
a.On or about August 3, 2010 - Employees working at Costco Store #356 were
exposed to the unexpected release of Freon-22, chemically referred to as
chlorodifluoromethane, as a result of leaks associated with the mechanical
refrigeration system.  A Freon R-22 leak detection system was not
installed at the
compressor/refrigeration machinery room.
Among other methods, one feasible and acceptable method to correct this
hazard is to provide
a detection system that would actuate an alarm and mechanical ventilation
at an exhaust rate
sufficient to remove vapors in accordance with the American Society of
Heating Refrigeration
and Air-Conditioning Engineers (ASHRAE), "Safety Code for Mechanical
Refrigeration",
Standard #15-2007.
Recent events (2)
  • · F (S) $6000.00
  • · Z (S) $6000.00

1910.120 Q01

Deleted Serious Gravity 05 1 instance 140 exposed
Issued
Dec 1, 2010
Abate by
Dec 20, 2010
Penalty
Initial $6,000 · Current $6,000
Recent events (2)
  • · F (S) $6000.00
  • · Z (S) $6000.00

1910.165 B03

Deleted Serious Gravity 05 1 instance 140 exposed
Issued
Dec 1, 2010
Abate by
Dec 20, 2010
Recent events (2)
  • · I (S)
  • · Z (S)

1910.1200 H03 III

Deleted Serious Gravity 05 1 instance 140 exposed
Issued
Dec 1, 2010
Abate by
Dec 20, 2010
Penalty
Initial $6,000 · Current $6,000
Recent events (2)
  • · F (S) $6000.00
  • · Z (S) $6000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 314557430.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.