Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HITE PARTS EXCHANGE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HITE PARTS EXCHANGE, INC. in 2235 MCKINLEY AVENUE, COLUMBUS, OH 43204 (NAICS 336399). OSHA activity number 314590555.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hite Parts Exchange, INC. — free Get an email when a new federal OSHA severe-injury report for Hite Parts Exchange, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2235 MCKINLEY AVENUE
City
COLUMBUS
State
OH
ZIP
43204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
SIC code (legacy)
3714
Employees
15
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 7 instances 3 exposed
Issued
Mar 30, 2011
Abate by
Aug 30, 2011
Penalty
Initial $3,000 · Current $1,050 Reduced

Hazardous substances A100

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to increased risk for injury related to fire, deflagration
and explosions because
methods were not used to ensure the proper collection, and prevent
ignition, of combustible dust
during aluminum metal parts processing related to abrasive blasting:
Hite Parts Exchange - McKinley Avenue, Columbus, Ohio facility:
a.As of and prior to January 6, 2011, the Goff Corporation 1848 dust
collector
used to collect dust from the 1 1/2 cube barrel blast machine (also known
as the
"zinc blaster) was located inside the building.
b.The dust collector was not properly bonded and grounded to minimize
static
electricity "charging" of the collection system. Additionally, the
filtration
media
used in the dust  collector was not designed for bonding and grounding to
dissipate static electric charge.
c.The dust collector ductwork had irregularities, in that a section of
unused
ductwork had been capped to create a "dead-end" section. This condition can
interrupt free airflow and allow for the build-up of material in these
sections of
the collection system ductwork.
d.The dust collector was not provided with proper deflagration venting to
a safe
location.
e.There were no signs posted to demarcate the dust collector as having
contents
posing an explosion hazard.
f.There were no systems or equipment in place to prevent propagation and
transmission of deflagration upstream of the collector in the ductwork.
g.Exhaust side air from the dust collector was recycling into the work
area.
ABATEMENT NOTE:
Among other methods, feasible and acceptable methods to correct this
hazard would be
to comply with the National Fire Protection Association (NFPA) 484
"Standard for
Combustible Metals" (2009 edition) and NFPA 69 "Standard on Explosion
Prevention
Systems" as they apply to your operations and equipment; including, but
not limited to,
the following, (1) locate dry type collectors outside of buildings (NFPA
484 section
6.3.2.5), (2) properly bond and ground dry-type dust collectors (NFPA 484
section
6.3.3.6), (3) install and maintain static charge dissipating filter media
in dry-type dust
collectors (NFPA 484 section 6.3.5.2), (4) properly design dust collector
ductwork
systems (NFPA 484 sections 6.3.3.5), (5) design and install properly sized
deflagration
venting (NFPA 484 section 6.3.5.6), (6) properly demarcate the dust
collector
withappropriate signage (NFPA 484 section 6.3.2.5.3), (7) evaluate and
implement an
explosion prevention and control system according to one or a combination
of the
methods found in NFPA 69 and (8) properly exhaust recycled air outside of
the building
(NFPA 484 section 6.3.6).
Recent events (2)
  • — I (S) $1050.00
  • — Z (S) $3000.00

1910.212 A03 II

Serious Gravity 05 1 instance 1 exposed
Issued
Mar 30, 2011
Abate by
May 16, 2011
Penalty
Initial $2,400 · Current $840 Reduced
Recent events (2)
  • — I (S) $840.00
  • — Z (S) $2400.00

1910.215 A02

Serious Gravity 01 1 instance 3 exposed
Issued
Mar 30, 2011
Abate by
Apr 4, 2011
Penalty
Initial $1,800 · Current $630 Reduced
Recent events (2)
  • — I (S) $630.00
  • — Z (S) $1800.00

1910.219 D01

Serious Gravity 01 1 instance 2 exposed
Issued
Mar 30, 2011
Abate by
Apr 14, 2011
Penalty
Initial $1,800 · Current $630 Reduced
Recent events (2)
  • — I (S) $630.00
  • — Z (S) $1800.00

1910.305 B02 I

Serious Gravity 05 1 instance 6 exposed
Issued
Mar 30, 2011
Abate by
Apr 4, 2011
Penalty
Initial $3,000 · Current $1,050 Reduced

Hazardous substances 8870

Recent events (2)
  • — I (S) $1050.00
  • — Z (S) $3000.00

View Hite Parts Exchange, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314590555.