Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DEL VAL TILE DISTRIBUTORS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEL VAL TILE DISTRIBUTORS in 1223 W. LINCOLN HIGHWAY, LANGHORNE, PA 19047 (NAICS 444190). OSHA activity number 314722505.

Watch DEL VAL Tile Distributors — free Get an email when a new federal OSHA severe-injury report for DEL VAL Tile Distributors is published. One employer, no account, unsubscribe in one click.
Site address
1223 W. LINCOLN HIGHWAY
City
LANGHORNE
State
PA
ZIP
19047
Mailing
1223 W. LINCOLN HIGHWAY, LANGHORNE, PA 19047
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
SIC code (legacy)
5211
Employees
8
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to crushing injuries due to unstable loads of steel storage rack:
a) Storage Area -  On or about February 11, 2011, a steel storage rack had
two of the
front upright frames placed on wooden blocks, exposing employees to the
hazard of
being crushed by unsecured rack components and stored materials while
working in the
vicinity of the overhead storage.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
method
to correct this hazard is:  The bottom of all columns shall be furnished
with column base plates
and shall be anchored to the floor with anchor bolts capable of resisting
the forces caused by the
horizontal and vertical loads on the rack. (Reference Paragraph 1.4.7,
MH16.1:2008,
Specification for the Design, Testing, and Utilization of Industrial Steel
Storage Racks)
Abatement certification required within 10 days after abatement date.  The
certification shall
include a statement that abatement is complete, date and method of
abatement, and states
employees and their representatives were informed of this abatement.tives

1910.178 L01 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Abate by

1910.178 P01

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Abate by

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314722505.