FT. MYERS, FL —
OSHA Inspection: POSEN CONSTRUCTION, INC,
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of POSEN CONSTRUCTION, INC, in COLONIAL BLVD.& I-75, FT. MYERS, FL 33916 (NAICS 237310). OSHA activity number 314736513.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POSEN CONSTRUCTION, INC,
- Site address
- COLONIAL BLVD.& I-75
- City
- FT. MYERS
- State
- FL
- ZIP
- 33916
- Mailing
- 9200 ESTERO PARK COMMONS BLVD., ESTERO, FL 33928
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- SIC code (legacy)
- 1622
- Employees
- 7
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 23, 2010
- Abate by
- Oct 5, 2010
- Penalty
- Initial $1,625 · Current $1,219 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards during dismantling of a crane boom. a) Site - Colonial Blvd/Forum Blvd. in Ft. Myers (FL); Equipment - Sumitomo Pile Driver Crawler Crane - Serial # LS238 - Model # LS238RH- 5. On or about 06/28/10 employees were exposed to being struck-by a section of crane boom falling during the dismantling process in that: 1. Sufficient dunnage was not placed under the boom peak and under both sides of every joint on the boom prior to removing the boom's lower connecting pins; 2. The pendant lines were not removed and re-anchored to a lower boom section prior to removing the boom's lower connecting pins; and, 3. The lower boom connecting pins were removed when the boom was not resting on the dunnage, but removed when the boom was in an elevated horizontal position above the dunnage. Among other methods, means of feasible and acceptable abatement include but may not be limited to: 1. Utilize the dismantling procedures listed in the Sumitomo Crane Operational Manual. 2. Utilize the dismantling procedures listed on page 65 & 66 of the Crane Handbook from the Construction Safety Association of Ontario, 1975 edition. 3. Train and ensure that employees utilize proper dismantling procedures when dismantling crane booms.
Recent events (2)
- — I (S) $1218.75
- — Z (S) $1625.00
1926.550 A06
- Issued
- Sep 23, 2010
- Abate by
- Oct 26, 2010
- Penalty
- Initial $1,625 · Current $1,219 Reduced
Recent events (2)
- — I (S) $1218.75
- — Z (S) $1625.00
More inspections at Posen Construction, INC,
View Posen Construction, INC,'s full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314736513.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.