HAVERHILL, MA —
OSHA Inspection: J & M TREE SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J & M TREE SERVICE in 871 BROADWAY STREET, HAVERHILL, MA 01832 (NAICS 561730). OSHA activity number 314794835.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & M TREE SERVICE
- Site address
- 871 BROADWAY STREET
- City
- HAVERHILL
- State
- MA
- ZIP
- 01832
- Mailing
- 5 NORWAY AVE, OLD ORCHARD BEACH, ME 04064
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- SIC code (legacy)
- 0783
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 7, 2010
- Abate by
- Oct 13, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards and aerial lift failure. (a) Location - Broadway Street, Haverhill, MA: On or about 9/2/10, the employer failed to maintain periodic inspection on a Reach All vehicle-mounted elevating and rotating aerial device. "AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS:" 1. The employer shall conduct periodic inspections on all insulated aerial lifts used for tree trimming operations. Vehicles, which have not received periodic dielectric inspections should not be dispatched to work crews working within 10 feet of power lines. (Reference: ANSI A92.2-1990, paragraph 8.2.4, American National Standard, Vehicle-Mounted Elevating and Rotating Devices) "ABATEMENT DOCUMENTATION REQUIRED FOR THIS CITATION"
1910.132 A
- Issued
- Oct 7, 2010
- Abate by
- Oct 12, 2010
- Penalty
- Initial $2,100 · Current $2,100
More inspections at J & M Tree Service
View J & M Tree Service's full OSHA safety record →
More inspections in this industry (NAICS 561730)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314794835.