Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IPS CORPORATION INC.

Accident-driven inspection · Health discipline

On , OSHA opened an accident-driven health inspection of IPS CORPORATION INC. in 600 ELLIS RD., DURHAM, NC 27703 (NAICS 325520). OSHA activity number 314877317.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IPS Corporation INC. — free Get an email when a new federal OSHA severe-injury report for IPS Corporation INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 ELLIS RD.
City
DURHAM
State
NC
ZIP
27703
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
SIC code (legacy)
2891
Employees
40
Ownership type
A
Industry flags
Manufacturing health.

2 citations on file for this inspection.

95012901

Serious 1 instance 1 exposed
Issued
May 12, 2011
Abate by
May 17, 2011
Penalty
Initial $6,300 · Current $4,725 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that
employees were exposed to:
a)At facility- in the mixing room, mixer No. 10, where on or about March
17, 2011, an
employee was exposed to a flash fire while preparing a batch. The employee
was dumping 30
pounds of plexi glass VS-100 (pellets) into a vessel that contained
flammable liquids. The
employee was using a plastic pail that was not bonded to the vessel and
the employee was not
being grounded.
Reference: NFPA 77, Recommended Practice on Static Electricity, 2007
edition, paragraphs 9.11.1.6 and
9.11.2: Powders should not be emptied from a non-conductive container in
the
presence of a flammable
atmosphere. Chapter 9.11.6 Personnel in the vicinity of openings of
vessels that contain flammable liquids
should be grounded.
Feasible and acceptable abatement methods to correct this hazard are to
require employees to ground themselves
by using wrist straps and the use of metal pails to dump powders and
solids that can be bonded to the vessels to
prevent electrostatic ignitions of fires and explosions and to provide
hands on training to ensure employees
attain the proper understanding of how to apply bonding and grounding
devices to eliminate the possibility of an
electrostatic discharge when handling flammables.ic
Recent events (2)
  • — I (S) $4725.00
  • — Z (S) $6300.00

1910.106 E06 I

Serious 1 instance 1 exposed
Issued
May 12, 2011
Abate by
May 17, 2011
Penalty
Initial $4,900 · Current $3,675 Reduced
Recent events (2)
  • — I (S) $3675.00
  • — Z (S) $4900.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314877317.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.