Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNO-FLO

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DYNO-FLO in 1180 CENTER POINT DRIVE, SUITE B, HENDERSON, NV 89074 (NAICS 441310). OSHA activity number 314887357.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dyno-Flo — free Get an email when a new federal OSHA severe-injury report for Dyno-Flo is published. One employer, no account, unsubscribe in one click.
Establishment
DYNO-FLO
Site address
1180 CENTER POINT DRIVE, SUITE B
City
HENDERSON
State
NV
ZIP
89074
Mailing
1180 CENTER POINT DRIVE, SUITE B, HENDERSON, NV 89074
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
SIC code (legacy)
5531
Employees
3
Ownership type
A
Industry flags
Manufacturing health.

5 citations on file for this inspection.

618037501

Serious Gravity 05 1 instance 1 exposed
Issued
Jun 8, 2011
Abate by
Jul 11, 2011
Penalty
Initial $3,000 · Current $3,000
Nevada Revised Statute 618.375(1): Every employer did not furnish employment and
a place of employment which was free from recognized hazards that were causing
or were likely to cause death or serious physical harm to his employees: (a) Dyn
o-Flo: The Shop Helper was exposed to injuries resulting from being struck by fr
agments of Schedule 40 Polyvinylchloride (PVC) pipe used to distribute compresse
d air at a pressure of 120 psig. PVC pipe is not recommended for compressed gas
distribution by the manufacturer because it is known to fail catastrophically. R
eference: PVC manufacturer's data, caution, and warning notices, which state: "D
o not use compressed air or gas for pressure testing","PVC and CPVC products are
not recommended for use in compressed air or gas systems", and "The manufacture
r does not recommend its PVC or CPVC products for use in compressed gas systems.
PVC and CPVC pipe, fittings, and valves
are excellent products for the transport of water and corrosive chemicals. But t
here are a number of other piping products that are especially designed and suit
ed for compressed air and gases." One feasible and acceptable method, among othe
rs, would be to replace the PVC pipe with a pipe capable of withstanding compres
sed air distribution.

1910.178 L01 I

Serious Gravity 05 1 instance 1 exposed
Issued
Jun 8, 2011
Abate by
Jul 11, 2011
Penalty
Initial $3,000 · Current $3,000

1910.1200 E01

Serious Gravity 05 1 instance 2 exposed
Issued
Jun 8, 2011
Abate by
Jul 11, 2011
Penalty
Initial $2,400 · Current $2,400

Hazardous substances 00400440104016602590

1910.1200 G01

Serious Gravity 05 1 instance 2 exposed
Issued
Jun 8, 2011
Abate by
Jun 13, 2011
Penalty
Initial $2,400 · Current $2,400

Hazardous substances 00401040138016602460

1910.1200 H01

Serious Gravity 05 1 instance 2 exposed
Issued
Jun 8, 2011
Abate by
Jul 11, 2011
Penalty
Initial $2,400 · Current $2,400

View Dyno-Flo's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314887357.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.