Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: R & S WELL SERVICES, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R & S WELL SERVICES, INC in SEC. 16-8N-2W, NORMAN, OK 73069 (NAICS 213112). OSHA activity number 314934712.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & S Well Services, INC for free Get an email when a new federal OSHA severe-injury report for R & S Well Services, INC is published. One employer, no account, unsubscribe in one click.
Site address
SEC. 16-8N-2W
City
NORMAN
State
OK
ZIP
73069
Mailing
P.O. BOX 721, HENNESSEY, OK 73742
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
4
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 14, 2011
Abate by
Oct 22, 2011
Penalty
Initial $4,200 · Current $2,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm:
The employer violated this standard on or about September 1, 2011 when the
R & S Well
Services, Inc, located that the Clarence Tullius and Frank Tullius Lease
Section 16-8N-2W in
Cleveland County, Oklahoma, did not ensure that employees performing work
in the rod
basket pulling rod were provided with emergency escape device to exit the
mast and derrick
in an emergency.
A feasible and acceptable method of abatement is to provide an emergency
escape device to
exit the mast and derrick in accordance with The American Petroleum
Institute (API),
Recommended Practice #54, for occupational safety for oil and gas well
drilling and
servicing operations, Section 6, Paragraph 10, Auxiliary Escape. This
section
states in
6.10.1: On all land rigs, the derrick or mast shall have an auxiliary
means of escape installed
prior to personnel working in the derrick.
Recent events (2)
  • · I (S) $2500.00
  • · Z (S) $4200.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 314934712.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.