HOLDENVILLE, OK ·
OSHA Inspection: SABER INDUSTRIES, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SABER INDUSTRIES, LP in BELL #1-8 SEC 8-7N-10E, HUGHES CTY, HOLDENVILLE, OK 74848 (NAICS 213112). OSHA activity number 314935958.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SABER INDUSTRIES, LP
- Site address
- BELL #1-8 SEC 8-7N-10E, HUGHES CTY
- City
- HOLDENVILLE
- State
- OK
- ZIP
- 74848
- Mailing
- 1505 N HARVEY ROAD, SEMINOLE, OK 74848
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 9
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 6, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $4,200 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: Well site: On or about October 13, 2011, employees operated a service rig during the workover of an oil/gas well. The rig was not adequately stabilized as three of four guylines anchors were inadequate and the two tubing board guylines were not attached to anchors. This exposed the employees to the hazards of an over turning rig, falling, and/or being struck by rig and well components. The American Petroleum Institute Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, RP 54, 6.3.2 requires that the rig be rigged up in a safe manner before starting well operations with the rig, and 9.2.10 requires that hazards is to assure that the rig is safely rigged up prior to the imposition of any operational load on the rig mast and that all the guylines are properly tensioned to certified anchors.d
Recent events (2)
- · I (S) $2000.00
- · Z (S) $4200.00
5(a)(1)
- Issued
- Mar 6, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $4,200 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: Well site: On or about October 13, 2011, an employee was working in the mast mounted rod basket on a service rig during the reworking of an oil/gas well where the secondary/emergency means of egress system was not completely installed. The escape device was not at the employee's work level and the ground end of system was not anchored preventing the employee from making timely egress from the rig mast. This exposed the employee to the hazards of explosion and fire, falling, and being struck by falling rig components. The America Petroleum Institute Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, RP54, 6.10.1 requires that an auxiliary means of escaped be installed on rig mast/derrick ant that it provides a ready and convenient means of escaped rom the derrickman's working platform. Among other methods, one feasible and acceptable abatement method to correct this hazard is to assure that the escape system is located at the employee's work elevation and that the system is installed in accordance with the manufacturer's instructions.s
Recent events (2)
- · I (S) $2000.00
- · Z (S) $4200.00
5(a)(1)
- Issued
- Mar 6, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $1,800 · Current $1,200 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: Well site: On or about October 13, 2011, employees operating a service rig during the rework of an oil/gas well worked with and around the unsecured well pumping unit. The control for the unit's electric motor was not locked in the off position and the counterweights were not restrained against movement. The American Petroleum Institute Recommended Practice for Occupational Safety for Onshore Oil and Gas Production Operations, RP 74, section 6.3.2.2, requires that the pumping unit be secured against unintended movement. Among other methods, one feasible and acceptable method to correct this hazard is to assure that pumping unit prime mover energy source is positively controlled and that the pumping unit is restrained from movement.d
Recent events (2)
- · I (S) $1200.00
- · Z (S) $1800.00
1910.132 A
- Issued
- Mar 6, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
Recent events (2)
- · I (S) $1200.00
- · Z (S) $2400.00
1910.133 A01
- Issued
- Mar 6, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
Recent events (2)
- · I (S) $1200.00
- · Z (S) $2400.00
1910.135 A01
- Issued
- Mar 6, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $1,800 · Current $1,200 Reduced
Recent events (2)
- · I (S) $1200.00
- · Z (S) $1800.00
1910.184 C14
- Issued
- Mar 6, 2012
- Abate by
- Mar 30, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
Recent events (2)
- · I (S) $1200.00
- · Z (S) $2400.00
1910.184 E01
- Issued
- Mar 6, 2012
- Abate by
- Mar 30, 2012
1910.184 E03 I
- Issued
- Mar 6, 2012
- Abate by
- Mar 30, 2012
1910.219 H01
- Issued
- Mar 6, 2012
- Abate by
- Mar 23, 2012
- Penalty
- Initial $1,800
Recent events (2)
- · I (O)
- · Z (S) $1800.00
1910.23 D01 III
- Issued
- Mar 6, 2012
- Abate by
- Mar 9, 2012
More inspections at Saber Industries, LP