YONKERS, NY —
OSHA Inspection: ELECTRONIC DEVICES, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ELECTRONIC DEVICES, INC. in 21 GREY OAKS AVE., YONKERS, NY 10710 (NAICS 334413). OSHA activity number 314979485.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELECTRONIC DEVICES, INC.
- Site address
- 21 GREY OAKS AVE.
- City
- YONKERS
- State
- NY
- ZIP
- 10710
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- SIC code (legacy)
- 3674
- Employees
- 26
- Ownership type
- A
Citations
16 citations on file for this inspection.
1910.1025 H01
- Issued
- Jan 5, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $3,500 · Current $2,450 Reduced
Recent events (2)
- — I (S) $2450.00
- — Z (S) $3500.00
1910.1027 K01
- Issued
- Jan 5, 2012
- Abate by
- Feb 8, 2012
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Nov 28, 2011
- Abate by
- Dec 13, 2011
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to incompatible chemicals being stored together resulting in the hazard of fire and explosion: a)Waste Water Treatment Room - Chemical Storage Area: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire and/or explosion. Seven boxes each containing 4 one-gallon containers of hydrogen peroxide (30%) were stored next to thirteen boxes each containing 4 one-gallon containers of hydrofluoric acid (49%) and eight boxes each containing 4 one- gallon containers of sulfuric acid (96%). b)Waste Water Treatment Room - Chemical Storage Area: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire and/or explosion. Eight boxes each containing 4 one-gallon containers of sulfuric acid were stored next to 3 boxes containing 4 one-gallon containers of ammonium hydroxide (29%). c)Waste Water Treatment Room - Chemical Storage Area: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire and/or explosion. A 1-gallon bottle of nitric acid (70%) was stored next to a 1-gallon bottle of sodium hydroxide (50%). d)White Room: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire. Thirteen (13) one-gallon containers of phosphoric acid (85%) were stored on the shelf above ten (10) one-gallon containers of hydrogen peroxide (30%). e)White Room: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire. Two 5-pound containers of sodium hydroxide pellets were stored on the shelf above fifteen one-gallon containers of acidic etch containing nitric acid and hydrofluoric acid. f)White Room: On or about 6/29/11; incompatible chemicals were stored together, creating the potential for fire and/or explosion. A one-pound container of chromium trioxide was stored next to five one-gallon containers of acidic etch containing nitric acid, hydrofluoric acid and glacial acetic acid. g)3rd Floor - Nickel Plating Room: On or about 7/28/11; incompatible chemicals were stored together, creating the potential for fire and/or explosion. A one- gallon container of ammonium hydroxide (29%) was stored next to a one-gallon container of nitric acid (70%), one-gallon container hydrofluoric acid (49%) and a one-gallon container of hydrochloric acid. h)3rd Floor - Storage Room: On or about 11/3/11; incompatible chemicals were stored together, creating the potential for fire. Four 1-gallon containers of ammonium hydroxide (29%) was stored above twenty one-gallon containers of hydrochloric acid (37%). i)3rd Floor - Storage Room: On or about 11/3/11; incompatible chemicals were stored together creating the potential for fire and/or explosion. A 1-gallon of bleach (sodium hypochlorite 5.25%) was stored next to a 1-gallon container of phosphoric acid (85%). NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. Among other feasbible methods the following methods of abatement would eliminate the hazard identified: 1. Physically separate incompatible chemicals.
Recent events (2)
- — I (S) $1000.00
- — Z (S) $3500.00
1910.132 A
- Issued
- Nov 28, 2011
- Abate by
- Dec 16, 2011
- Penalty
- Initial $3,500 · Current $3,000 Reduced
Recent events (2)
- — I (S) $3000.00
- — Z (S) $3500.00
1910.138 A
- Issued
- Nov 28, 2011
- Abate by
- Dec 13, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.133 A01
- Issued
- Nov 28, 2011
- Abate by
- Dec 16, 2011
- Penalty
- Initial $3,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $3500.00
1910.146 C01
- Issued
- Nov 28, 2011
- Abate by
- Jan 2, 2012
- Penalty
- Initial $3,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $3500.00
1910.146 C02
- Issued
- Nov 28, 2011
- Abate by
- Jan 2, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Nov 28, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $2,800 · Current $3,000
Recent events (2)
- — I (S) $3000.00
- — Z (S) $2800.00
1910.1200 F05 I
- Issued
- Nov 28, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $3,500 · Current $3,000 Reduced
Recent events (2)
- — I (S) $3000.00
- — Z (S) $3500.00
1910.1200 F05 II
- Issued
- Nov 28, 2011
- Abate by
- Dec 1, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H01
- Issued
- Nov 28, 2011
- Abate by
- Dec 1, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H03 III
- Issued
- Nov 28, 2011
- Abate by
- Dec 16, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.22 A01
- Issued
- Nov 28, 2011
- Abate by
- Dec 1, 2011
Recent events (2)
- — I (O)
- — Z (O)
1910.134 C01
- Issued
- Nov 28, 2011
- Abate by
- Jan 2, 2012
Recent events (2)
- — I (O)
- — Z (O)
1910.134 E01
- Issued
- Nov 28, 2011
- Abate by
- Jan 2, 2012
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Electronic Devices, INC.
View Electronic Devices, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334413)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314979485.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.