Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRONIC DEVICES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ELECTRONIC DEVICES, INC. in 21 GREY OAKS AVE., YONKERS, NY 10710 (NAICS 334413). OSHA activity number 314979485.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electronic Devices, INC. — free Get an email when a new federal OSHA severe-injury report for Electronic Devices, INC. is published. One employer, no account, unsubscribe in one click.
Site address
21 GREY OAKS AVE.
City
YONKERS
State
NY
ZIP
10710
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334413
SIC code (legacy)
3674
Employees
26
Ownership type
A

16 citations on file for this inspection.

1910.1025 H01

Serious Gravity 05 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Feb 8, 2012
Penalty
Initial $3,500 · Current $2,450 Reduced
Recent events (2)
  • — I (S) $2450.00
  • — Z (S) $3500.00

1910.1027 K01

Serious Gravity 05 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Feb 8, 2012
Recent events (2)
  • — I (S)
  • — Z (S)

5(a)(1)

Serious Gravity 05 9 instances 26 exposed
Issued
Nov 28, 2011
Abate by
Dec 13, 2011
Penalty
Initial $3,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to incompatible chemicals being stored together resulting in
the hazard of fire and
explosion:
a)Waste Water Treatment Room - Chemical Storage Area:  On or about 6/29/11;
incompatible chemicals were stored together, creating the potential for
fire and/or
explosion.  Seven boxes each containing 4 one-gallon containers of hydrogen
peroxide (30%) were stored next to thirteen boxes each containing 4
one-gallon
containers of hydrofluoric acid (49%) and eight boxes each containing 4
one-
gallon containers of sulfuric acid (96%).
b)Waste Water Treatment Room - Chemical Storage Area:  On or about 6/29/11;
incompatible chemicals were stored together, creating the potential for
fire and/or
explosion.  Eight boxes each containing 4 one-gallon containers of
sulfuric acid
were stored next to 3 boxes containing 4 one-gallon containers of ammonium
hydroxide (29%).
c)Waste Water Treatment Room - Chemical Storage Area:  On or about 6/29/11;
incompatible chemicals were stored together, creating the potential for
fire and/or
explosion.  A 1-gallon bottle of nitric acid (70%) was stored next to a
1-gallon
bottle of sodium hydroxide (50%).
d)White Room:  On or about 6/29/11; incompatible chemicals were stored
together,
creating the potential for fire.  Thirteen (13) one-gallon containers of
phosphoric
acid (85%) were stored on the shelf above ten (10) one-gallon containers of
hydrogen peroxide (30%).
e)White Room:  On or about 6/29/11; incompatible chemicals were stored
together,
creating the potential for fire.  Two 5-pound containers of sodium
hydroxide
pellets were stored on the shelf above fifteen one-gallon containers of
acidic etch
containing nitric acid and hydrofluoric acid.
f)White Room:  On or about 6/29/11; incompatible chemicals were stored
together,
creating the potential for fire and/or explosion.  A one-pound container of
chromium trioxide was stored next to five one-gallon containers of acidic
etch
containing nitric acid, hydrofluoric acid and glacial acetic acid.
g)3rd Floor - Nickel Plating Room:  On or about 7/28/11; incompatible
chemicals
were stored together, creating the potential for fire and/or explosion.  A
one-
gallon container of ammonium hydroxide (29%) was stored next to a
one-gallon
container of nitric acid (70%), one-gallon container hydrofluoric acid
(49%) and
a one-gallon container of hydrochloric acid.
h)3rd Floor - Storage Room:  On or about 11/3/11; incompatible chemicals
were
stored together, creating the potential for fire.  Four 1-gallon
containers of
ammonium hydroxide (29%) was stored above twenty one-gallon containers of
hydrochloric acid (37%).
i)3rd Floor - Storage Room:  On or about 11/3/11; incompatible chemicals
were
stored together creating the potential for fire and/or explosion.  A
1-gallon of
bleach (sodium hypochlorite 5.25%) was stored next to a 1-gallon container
of
phosphoric acid (85%).
NOTE: The employer is required to submit abatement certification for this
item in
accordance with 29 CFR 1903.19.
Among other feasbible methods the following methods of abatement would
eliminate
the hazard
identified:
1. Physically separate incompatible chemicals.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $3500.00

1910.132 A

Serious Gravity 05 4 instances 4 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $3,500 · Current $3,000 Reduced
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $3500.00

1910.138 A

Serious Gravity 05 1 instance 1 exposed
Issued
Nov 28, 2011
Abate by
Dec 13, 2011
Recent events (2)
  • — I (S)
  • — Z (S)

1910.133 A01

Serious Gravity 05 6 instances 6 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $3,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $3500.00

1910.146 C01

Serious Gravity 05 1 instance 1 exposed
Issued
Nov 28, 2011
Abate by
Jan 2, 2012
Penalty
Initial $3,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $3500.00

1910.146 C02

Serious Gravity 05 1 instance 1 exposed
Issued
Nov 28, 2011
Abate by
Jan 2, 2012
Recent events (2)
  • — I (S)
  • — Z (S)

1910.151 C

Serious Gravity 05 3 instances 4 exposed
Issued
Nov 28, 2011
Abate by
Dec 1, 2011
Penalty
Initial $2,800 · Current $3,000
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $2800.00

1910.1200 F05 I

Serious Gravity 05 1 instance 2 exposed
Issued
Nov 28, 2011
Abate by
Dec 1, 2011
Penalty
Initial $3,500 · Current $3,000 Reduced
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $3500.00

1910.1200 F05 II

Serious Gravity 05 1 instance 2 exposed
Issued
Nov 28, 2011
Abate by
Dec 1, 2011
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H01

Serious Gravity 05 3 instances 6 exposed
Issued
Nov 28, 2011
Abate by
Dec 1, 2011
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H03 III

Serious Gravity 05 4 instances 5 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Recent events (2)
  • — I (S)
  • — Z (S)

1910.22 A01

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Nov 28, 2011
Abate by
Dec 1, 2011
Recent events (2)
  • — I (O)
  • — Z (O)

1910.134 C01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Nov 28, 2011
Abate by
Jan 2, 2012
Recent events (2)
  • — I (O)
  • — Z (O)

1910.134 E01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Nov 28, 2011
Abate by
Jan 2, 2012
Recent events (2)
  • — I (O)
  • — Z (O)

View Electronic Devices, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314979485.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.