POCATELLO, ID —
OSHA Inspection: J. R. SIMPLOT COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J. R. SIMPLOT COMPANY in 1150 W. HIGHWAY 30, POCATELLO, ID 83204 (NAICS 325311). OSHA activity number 315027292.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. R. SIMPLOT COMPANY
- Site address
- 1150 W. HIGHWAY 30
- City
- POCATELLO
- State
- ID
- ZIP
- 83204
- Mailing
- POST OFFICE BOX 912, POCATELLO, ID 83204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325311
- SIC code (legacy)
- 2873
- Employees
- 350
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 D03 II
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complied with recognized and generally accepted good engineering practices (RAGAGEP). a.Pipe Bridge Between 300 Sulfuric and Liquid Plant: On or about January 5, 2011, and at times prior thereto, the employer did not document that overhead piping containing anhydrous ammonia complied with RAGAGEP in that, the pipe was observed to be shaking and swaying above a vehicle and pedestrian road. b.Anhydrous Ammonia Atmospheric Tank: On or about January 5, 2011, and at times prior thereto, the employer did not document that discharge piping complied with RAGAGEP in that, the height and position of the hydrostatic discharge exposed employees working under or in the vicinity of the discharge to anhydrous ammonia. c.Sulfuric Acid Plant #300: On or about January 5, 2011, and at times prior thereto, the employer did not document that valve labeling complied with RAGAGEP in that, valve "V-021" marked on P&ID JRS-6733-F-134.2 was not labeled in the field. d.Sulfuric Acid Plant #300: On or about January 5, 2011, and at times prior thereto, the employer did not document that piping complied with RAGAGEP in that, the hydrostatic relief misplacement of PV-019 renders the pipe between V-015 and V-017 unprotected from over pressure. Abatement Note: Among other methods to comply with recognized and generally acceptable good engineering practices the employer may consider the following: Ensure all piping is supported per ANSI K61.1, Requirement for the Storage and Handling of Anhydrous Ammonia, and ASME B31.1., Power Piping, to prevent sagging, mechanical injury and unusual service conditions. Ensure discharge piping is positioned to discharge to a safe location per API 2000, Venting Atmospheric & Low Pressure Storage Tanks: Nonrefrigerated & Refrigerated. Ensure valves are labeled per ASME A13.1, Scheme for Identification of Piping Systems. Ensure piping is protected per ANSI K61.1, Requirements for the Storage and Handling of Anhydrous Ammonia. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $4000.00
- — Z (S) $5500.00
1910.119 E03 I
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(i): The process hazard analysis did not address all hazards associated with the process: a.Water Treatment Plant: On or about January 5, 2011, and at times prior thereto, the process hazard analysis did not address equipment damage that may result from employees stepping over anhydrous ammonia piping to access the water treatment building.V Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $4000.00
- — Z (S) $5500.00
1910.119 F01 IB
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $7,000
General-duty citation text
29 CFR 1910.119(f)(1)(i)(B): The employer did not develop and implement written normal operating procedures for safely conducting activities involved in each covered process: a.Ammonia Operations: On or about January 3, 2011, and at times prior thereto, normal operating procedures for the Ammsox plant had not been developed. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S)
- — Z (S) $7000.00
1910.119 F01 ID
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
General-duty citation text
29 CFR 1910.119(f)(1)(i)(D): The employer did not develop and implement written operating procedures for emergency shutdown including conditions under which emergency shutdown is required and the assignment of shutdown responsibilities to qualified operators: a.Ammonia Operations: On or about January 3, 2011, and at times prior thereto, emergency shutdown procedures for the sulfuric acid plant did not address shutting down the Ammsox system. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S)
- — Z (S)
1910.119 F03
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $7,000
General-duty citation text
29 CFR 1910.119(f)(3): The operating procedures were not reviewed as often as necessary to assure that they reflect current operating practice, including changes that result from changes in process chemicals, technology, and equipment, and changes to facilities. The employer did not certify annually that these operating procedures are current and accurate. a.Ammonia Operations: On or about January 3, 2011, and at times prior thereto, an annual certification had not been developed for operating procedures such as, but not limited to, the normal shutdown procedures for the ammonia system. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S)
- — Z (S) $7000.00
1910.119 D03 IB
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $38,500 · Current $20,000 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Information pertaining to the equipment in the process does not include piping and instrument diagrams (P&IDs). a.Outside Ammonia High Pressure Storage Tanks: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6822-F-120.1, was not accurate since the P&ID indicated a pipe reduction from one inch to one-half inch and one-quarter inch at V-547. The pipe reduction did not exist in the field. b.Outside Ammonia High Pressure Storage Tanks: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6822-F-120.1, was not accurate since a pipe reduction from a three inch pipe near V-574 that was observed in the field, was not included on the P&ID. c.Outside Ammonia High Pressure Storage Tanks: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6822-F-120.1, was not accurate since the PV-042 on the P&ID was actually tagged as V-456 in the field. d.Outside Ammonia High Pressure Storage Tanks: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6822-F-120.1, was not accurate since the P&ID did not contain a label for a gate valve which was tagged as V-589 in the field. e.Outside Ammonia High Pressure Storage Tanks: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6822-F-120.1, was not accurate since the valves labeled as V-515 and V-514 on the P&ID, did not correspond to the identification tags observed in the field. f.Ammonia Low Pressure Storage: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6825-F-161.1, was not accurate since a pressure valve (PV) actuator located near V-067 on the P&ID did not exist in the field. g.Ammonia Low Pressure Storage: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-6825-F-161.1, was not accurate since V-067 on the P&ID was not located in the same location in the field. h.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since a gate valve shown on the Unloading Line, "3" AL-901-SLA-903" did not exist in the field. i.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since a threaded cap shown on the Unloading Line, "3" AL-901-SLA-903" did not exist in the field. j.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since the temperature indicator (TI) 6800-7349 was actually located downstream of thetemperature element (TE) 6800-7350 on "4" AL-901-SLA-903". k.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since a pipe reduction from three inches to one-quarter inch shown between V-056 and V-055 did not exist in the field. l.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since a temperature point (TP) shown at "AMMONIA XFER PUMP" "JRS-6825-F-161.1" was not labeled on the P&ID. m.Ammonia Low Pressure Storage: On or about January 5, 2011 and at times prior thereto, the P&ID marked as JRS-6825-F-161.8, was not accurate since a temperature point (TP) shown at "RELIEF HEADER" "JRS-6825-F-161.7" was not labeled on either side of the P&ID. n.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since valves labeled V-763 and V-764 on the P&ID, did not correspond to the identification tags observed in the field. o.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since the P&ID did not indicate a pipe containing a gate valve and check valve which were located between V-763 and V-764 in the field. p.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since the valve labeled as VR-053 on the P&ID, did not correspond to the identification tag of VR-052 observed in the field. q.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since the P&ID did not contain V-768 which was observed in the field. r.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since V- 768 was actually located downstream from the location indicated on the P&ID. s.Ammonium Phosphate Plant #100-Granualtion: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7011-F-122, was not accurate since the P&ID did not contain complete pipe labeling or size indications. Several pipe labels on the P&ID contained notes such as: "1/2 " AL-066-P??-??-?" or "?" ??-079-P???- ??-?". t.Ammonium Phosphate Plant #100-Granulation Building: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-7015-F-128.1, was not accurate since the valves labeled 773, 774, 783 and 784 on the P&ID, did not correspond to the identification tags observed in the plant. u.Ammonia Loading Dock: On or about January 5, 2011, and at times prior thereto, the P&ID marked as JRS-8555-F-100.1, was not accurate since piping labeled as "3" AL-SLA-904" on the P&ID was observed to be a four-inch line in the field. The J.R. Simplot Company, was previously cited for a violation of this occupational safety and health standard, which was contained in inspection number 314172024, citation 1, item 2A and was affirmed as a final order on November 8, 2010, with respect to a workplace located at 3630 Gateway Drive, Grand Forks, North Dakota. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $20000.00
- — Z (R) $38500.00
1910.119 L04
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
General-duty citation text
29 CFR 1910.119(l)(4): For a change resulting in a change to the process safety information required by paragraph (d) of this section, the employer had not updated the process safety information accordingly: a.Administrative: On or about January 3, 2011, and at times prior thereto, the process safety information contained a piping and instrument diagram (P&ID) marked as JRS- 6822-F-120.1, Revision 8. The process safety information had not been updated to include the most current revision, Revision 11. b.Administrative: On or about January 3, 2011, and at times prior thereto, the process safety information contained a piping and instrument diagram (P&ID) marked as JRS- 6822-F-120.2, Revision 5. The process safety information had not been updated to include the most current revision, Revision 9. The J.R. Simplot Company, was previously cited for a violation of this occupational safety and health standard, which was contained in inspection number 311577613, citation 1, item 7 and was affirmed as a final order on October 27, 2008, with respect to a workplace located at 1150 W. Highway 30, Pocatello, Idaho. Note: Abatement certification and supporting documentation are required for this item.
Recent events (2)
- — I (R)
- — Z (R)
1910.151 C
- Issued
- May 3, 2011
- Abate by
- May 27, 2011
- Penalty
- Initial $15,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a.Ammonia Compressor Room. On or about January 3, 2011 and at times prior thereto, the emergency eyewash and shower inside the compressor room was frozen. Employees were changing the compressor oil and were exposed to the anhydrous ammonia. b.Ammonia Railcar Unloading: On or about January 3, 2011 and at times prior thereto, the emergency eyewash and shower were frozen, exposing the employees to anhydrous ammonia. The J.R. Simplot Company, was previously cited for a violation of this occupational safety and health standard, which was contained in inspection number 311577605, citation 2, item 2 and was affirmed as a final order on October 27, 2008, with respect to a workplace located at 1150 W. Highway 30, Pocatello, Idaho. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $4000.00
- — Z (R) $15000.00
More inspections at J. R. Simplot Company
View J. R. Simplot Company's full OSHA safety record →
More inspections in this industry (NAICS 325311)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315027292.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.