SALISBURY, MD ·
OSHA Inspection: BOUNDS-ELECTRIC CO INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BOUNDS-ELECTRIC CO INC in 105 EAST NORTH POINT DRIVE, SALISBURY, MD 21801 (NAICS 561790). OSHA activity number 315052357.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOUNDS-ELECTRIC CO INC
- Site address
- 105 EAST NORTH POINT DRIVE
- City
- SALISBURY
- State
- MD
- ZIP
- 21801
- Mailing
- 6499 MARY JANE DRIVE, SALISBURY, MD 21801
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.67 C02 II
- Issued
- Nov 8, 2010
- Abate by
- Dec 23, 2010
- Penalty
- Initial $900 · Current $900
1910.67 C02 V
- Issued
- Nov 8, 2010
- Abate by
- Nov 16, 2010
1910.67 C02 IX
- Issued
- Nov 8, 2010
- Abate by
- Nov 16, 2010
- Penalty
- Initial $900 · Current $900
1910.135 A01
- Issued
- Nov 8, 2010
- Abate by
- Nov 16, 2010
- Penalty
- Initial $900 · Current $900
50104 A
- Issued
- Nov 8, 2010
- Abate by
- Nov 16, 2010
- Penalty
- Initial $1,050 · Current $1,050
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:09/10/10 Location:Parking Lot Equipment:Holan, 58-foot, Articulating Boom Aerial Platform Truck, Serial #81-23949 Condition:Employees were exposed to being crushed by collapsing/failing boom since recommended inspection/maintenance schedule, as established by the manufacturer, were not followed resulting in visible problems such as boom rust, broken and rusted controls, exposed circuit breakers and disconnected wiring, missing and non original equipment manufacturer or equivalent bolts, leaking hydraulic cylinder and asociated hydraulic system defects. Among other methods. one feasible and acceptable method to correct this hazard is to comply with the manufacturer's instructions regarding established inspection and maintenance schedules to assure that the aerial lift equipment is maintained in safe operating condition and the American National Standard Institutes " Vehicle Mounted Elevating and Rotating Work Platforms" ANSI A 92.2-1969, Section 5 requirements entitled "Testing and Inspection". Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
More inspections in this industry (NAICS 561790)
More inspections in MD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315052357.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.