FANNIN, TX —
OSHA Inspection: BASIC ENERGY SERVICES, INC., RIG NUMBER 1352
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BASIC ENERGY SERVICES, INC., RIG NUMBER 1352 in FM HWY 2987 TO FANNIN OAKS DRIVE, FANNIN, TX 77963 (NAICS 213112). OSHA activity number 315098947.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BASIC ENERGY SERVICES, INC., RIG NUMBER 1352
- Site address
- FM HWY 2987 TO FANNIN OAKS DRIVE
- City
- FANNIN
- State
- TX
- ZIP
- 77963
- Mailing
- 5606 NORTH NAVARRO STREET, SUITE 306, VICTORIA, TX 77904
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 26, 2011
- Abate by
- May 20, 2011
- Penalty
- Initial $5,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to a struck-by hazard: The employer does not conduct Inspection & Repair on pressure relief devices. This violation was last observed on or about November 3, 2010 and at times prior thereto when inspections had not been conducted in accordance to API 510 on the relief valve for the National 340 mud pump. Among other methods, one feasible method to abate this violation is: *The employer must develop an inspection policy for pressure relief valves as well as for pressure vessels. *The policy must contain procedures for dismantling of the valves; *The policy must contain requirements regarding qualifications of the valve shop as well as qualification for the craft that perform inspection and repair of relief valve. *The policy must contain requirements to test the relief valve prior to dismantling of the valves and also testing of the valves following the repair work, in accordance to API 574. *The policy must contain requirements for routine inspection of the relief valve. Pursuant to 29 CFR 1903.19 within ten (10) days of this citation, the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure Inspection & Repair are conducted on safety relief valves.
Recent events (2)
- — F (S)
- — Z (S) $5500.00
1910.23 C01
- Issued
- Apr 26, 2011
- Abate by
- May 2, 2011
- Penalty
- Initial $5,500 · Current $5,500
Recent events (2)
- — F (S) $5500.00
- — Z (S) $5500.00
1910.151 B
- Issued
- Apr 26, 2011
- Abate by
- May 2, 2011
- Penalty
- Initial $5,500
Recent events (2)
- — F (S)
- — Z (S) $5500.00
5(a)(1)
- Issued
- Apr 26, 2011
- Abate by
- May 2, 2011
- Penalty
- Initial $38,500 · Current $26,950 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to a fall hazard: The employer does not provide a safe means of egress from the pipe racking board. This violation last occurred on or about October 26, 2010 and at times prior thereto when employees were removing two and three-eighths inch production tubing from the wellbore in preparation for perforation of the casing at a new zone. Basic Energy Servies, Inc., Rig Number 1352 was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 310903422, citation number 01, item number 001 and was affirmed as a final order on 07/10/07, with respect to a workplace located at IH 37, Corpus Christi, Texas 78409. Pursuant to 29 CFR 1903.19 within ten (10) days of the date of this citation, the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure the correct and proper installation of the one-half inch wire rope Geronimo Emergency Escape Line, to the anchor.
Recent events (2)
- — F (R) $26950.00
- — Z (R) $38500.00
1910.242 A
- Issued
- Apr 26, 2011
- Abate by
- May 2, 2011
- Penalty
- Initial $22,000 · Current $7,000 Reduced
Recent events (2)
- — F (S) $7000.00
- — Z (R) $22000.00
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315098947.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.