Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JENKINS ELECTRIC INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JENKINS ELECTRIC INC. in BASSINGER LONG 5 B, GARZA COUNTY, TX 79356 (NAICS 238210). OSHA activity number 315277731.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jenkins Electric INC. — free Get an email when a new federal OSHA severe-injury report for Jenkins Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
BASSINGER LONG 5 B
City
GARZA COUNTY
State
TX
ZIP
79356
Mailing
P. O. BOX 236, POST, TX 79356
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 7, 2011
Abate by
Mar 1, 2012
Penalty
Initial $4,620 · Current $3,234 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized
hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the condition(s) listed below:
On or about 08/18/2011 and at times prior thereto, at the jobsite located
at Bassinger Long 5
B Garza County, TX., employees were exposed to crush-by hazards while
working on a pump
jack that had not been secured to prevent unintended movement.
Among other methods, recognized and feasible means to correct this hazard
include, but are not
limited to: The employer can follow the recommendations of the American
Petroleum Institute
Recommended Practice 74 para. 6.3.2.2 which states "During well servicing
operations, the
pumping unit shall be secured to prevent unintended movement. Use of the
brake only or the
brake and brake pawl are not acceptable means of securing the pumping
unit."g
Recent events (2)
  • — I (S) $3234.00
  • — Z (S) $4620.00

View Jenkins Electric INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315277731.