RICHLAND, MS —
OSHA Inspection: AZTEC INDUSTRIES, INC. DBA AZZ GALVANIZING - JACKS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AZTEC INDUSTRIES, INC. DBA AZZ GALVANIZING - JACKS in 125 AZTEC DRIVE, RICHLAND, MS 39218 (NAICS 332812). OSHA activity number 315306381.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AZTEC INDUSTRIES, INC. DBA AZZ GALVANIZING - JACKS
- Site address
- 125 AZTEC DRIVE
- City
- RICHLAND
- State
- MS
- ZIP
- 39218
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- SIC code (legacy)
- 3479
- Employees
- 27
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- May 31, 2012
- Abate by
- Jun 26, 2012
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to an eye injury. (a)Kettle Area - On or about December 22, 2011 eye wash station no. 2 had a flushing fluid flow pressure of 48 pounds per square inch (psi) which exceeded ANSI requirement of 30 psi of flow pressure. The eye wash was not protected from freezing during freezing conditions. (b)Outside East Wall - On or about December 22, 2011 eye wash station no. 3 had a flushing fluid flow pressure of 50 pounds per square inch (psi) which exceeded ANSI requirement of 30 psi of flow pressure. The eye wash was not protected from freezing during freezing conditions. One feasible and acceptable abatement method would be to comply with ANSI Z358.1-1998 to ensure that the supply line provide an uninterruptible supply of flushing fluid at 30 pounds per square inch of flow pressure. Where the possibility of freezing conditions exists, equipment shall be protected from freezing or freeze protected equipment shall be installed.
Recent events (2)
- — I (S) $4400.00
- — Z (S) $4400.00
1910.95 C01
- Issued
- May 31, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $6,600 · Current $4,000 Reduced
Recent events (3)
- — P (S) $4000.00
- — I (S) $4000.00
- — Z (S) $6600.00
1910.1200 F05 II
- Issued
- May 31, 2012
- Abate by
- Jun 12, 2012