JACKSONVILLE, NC —
OSHA Inspection: BILLED OUT CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BILLED OUT CONSTRUCTION, INC. in BUILDING 8 KENAN LOOP, JACKSONVILLE, NC 28546 (NAICS 238130). OSHA activity number 315449959.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BILLED OUT CONSTRUCTION, INC.
- Site address
- BUILDING 8 KENAN LOOP
- City
- JACKSONVILLE
- State
- NC
- ZIP
- 28546
- Mailing
- 198 JONES ST, CEDAR POINT, NC 28584
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 14
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
11 citations on file for this inspection.
95012901
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $1,400 · Current $1,050 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falls from elevation and struck by hazards: a)job site - 2 employees were working within the truss web to install trusses and decking at a peak height of 22 feet and an eve height of 16 feet above the ground. The trusses were not stabilized against roll/collapse in that they had not been provided with proper restraint/bracing for the top chord, web member plane, or bottom chord. ABATEMENT NOTE: 1)Among other methods, one feasible and acceptable abatement method to correct these hazards is to provide and install diagonal and/or lateral bracing to the top chord, web member plane, or bottom chord. . This can be accomplished by following the instructions in The Truss Installation and Temporary Bracing of the Truss Plate Institute that were provided by the truss manufacturer and were available on the job site or have a professional engineer design a temporary bracing system. This diagonal bracing would stabilize and strengthen the truss system to permit workers to be on or inside the web to complete the installation. An explanation of the use of diagonal/lateral bracing is also included in OPN 109B, which was provided by the CSHO. Reference:Hazards recognized and addressed in the industry standard Commentary and Recommendations for Handling, Installing, and Bracing Metal Connected Wood Trusses by Truss Plate Institute (HIB091) and the Truss Installation and Temporary Bracing by Truss Plate Institute (BCSI-B1, 2, and 3).
Recent events (2)
- — I (S) $1050.00
- — Z (S) $1400.00
1926.501 C
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $300 · Current $225 Reduced
Recent events (2)
- — I (S) $225.00
- — Z (S) $300.00
1926.502 D15
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $1,400 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $1400.00
1926.501 B13
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
Recent events (2)
- — I (S)
- — Z (S)
1926.20 B02
- Issued
- Mar 2, 2012
- Abate by
- Apr 18, 2012
Recent events (2)
- — I (S)
- — Z (S)
1926.503 A02
- Issued
- Mar 2, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $1,400 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $1400.00
1926.503 B01
- Issued
- Mar 2, 2012
- Abate by
- Apr 18, 2012
Recent events (2)
- — I (S)
- — Z (S)
1926.150 C01 I
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 E01
- Issued
- Mar 2, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $150 · Current $113 Reduced
Recent events (2)
- — I (O) $113.00
- — Z (O) $150.00
1910.1200 G01
- Issued
- Mar 2, 2012
- Abate by
- Mar 7, 2012
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 H01
- Issued
- Mar 2, 2012
- Abate by
- Mar 28, 2012
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Billed OUT Construction, INC.