JOHNSTOWN, PA ·
OSHA Inspection: THE MOXHAM LUMBER CO.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THE MOXHAM LUMBER CO. in 150 DUPONT STREET, JOHNSTOWN, PA 15902 (NAICS 337110). OSHA activity number 315564450.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE MOXHAM LUMBER CO.
- Site address
- 150 DUPONT STREET
- City
- JOHNSTOWN
- State
- PA
- ZIP
- 15902
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 5712
- Employees
- 17
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 23, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
E200E101
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration, and fire hazards: (a)In the facility, on or about February 22, 2012 - Woodworking equipment such as a belt sander generates sparks. Wood debris from this equipment enters metal duct work. This duct work is not equipped with a listed spark detection system. (b)In the facility, on or about February 22, 2012 - The hopper used to collect the wood dust was constructed entirely of wood. (c)In the facility, on or about February 22, 2012 - The employer did not retain the records relating to its dust collection system. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS IS TO COMPLY WITH NATIONAL FIRE AND PROTECTION AGENCY (NFPA) 664, STANDARDS FOR THE PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES (2007) INCLUDING, BUT NOT LIMITED TO: * INSTALL DUCTS WITH A FIRE HAZARD CAPABLE OF CONVEYING DRY MATERIAL RELEASED BY EQUIPMENT, SUCH AS A BELT SANDER, WHICH HAVE THE HIGH FREQUENCY OF GENERATED SPARKS WERE NOT DESIGNED AND CONSTRUCTED TO BE EQUIPPED WITH A LISTED SPARK DETECTION SYSTEM ACTUATING A HIGH SPEED ABORT GATE, PROVIDED THE ABORT GATE CAN OPERATE FAST ENOUGH TO INTERCEPT AND DIVERT BURNING EMBERS TO ATMOSPHERE BEFORE THEY CAN ENTER ANY COLLECTION OR STORAGE EQUIPMENT AS LISTED IN CHAPTER 8, PARAGRAPH 8.2.2.2.2 OF NFPA 664. *DESIGN AND CONSTRUCT THE COLLECTION EQUIPMENT ENTIRELY OF NONCOMBUSTIBLE MATERIAL SUITABLE FOR THE USE INTENDED AS LISTED IN CHAPTER 8, PARAGRAPH 8.2.2.5.1.2 OF NFPA 664. *REQUIRE AND RETAIN THE RECORDS TO INCLUDE, BUT NOT LIMITED TO, DRAWINGS AND SUPPORTING DOCUMENTS RELATING TO INITIAL INSTALLATION/PURCHASE OF EQUIPMENT, ROUTINE EQUIPMENT INSPECTIONS, TESTING AND REPAIR, HISTORY, FIRE AND SAFETY INSPECTION OR AUDIT REPORTS, SERVICE RECORDS, AND MANUFACTURER'S DATA SHEETS AS LISTED IN CHAPTER 10, PARAGRAPH 10.3.1 OF NFPA 664.
Recent events (2)
- · F (S) $2100.00
- · Z (S) $4200.00
1910.22 A01
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
E200E101
Recent events (2)
- · F (S) $1500.00
- · Z (S) $3000.00
1910.133 A01
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
Recent events (2)
- · F (S) $900.00
- · Z (S) $1800.00
1910.307 C
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
E200E101
Recent events (2)
- · F (S) $900.00
- · Z (S) $1800.00
1910.37 B04
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
Recent events (2)
- · F (O)
- · Z (O)
1910.134 C02 II
- Issued
- Jul 23, 2012
- Abate by
- Aug 27, 2012
Recent events (2)
- · F (O)
- · Z (O)
1910.157 C01
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
E200E101
Recent events (2)
- · F (O)
- · Z (O)
1910.303 E01 II
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
Recent events (2)
- · F (O)
- · Z (O)
1910.303 G01 II
- Issued
- Jul 23, 2012
- Abate by
- Aug 10, 2012
Recent events (2)
- · F (O)
- · Z (O)
More inspections in this industry (NAICS 337110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 315564450.