Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED ELECTRICAL CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED ELECTRICAL CONSTRUCTION, INC. in 8530 PERRY HIGHWAY, PITTSBURGH, PA 15102 (NAICS 238210). OSHA activity number 315565127.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Electrical Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced Electrical Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8530 PERRY HIGHWAY
City
PITTSBURGH
State
PA
ZIP
15102
Mailing
2508 DRIFTWOOD DRIVE, BETHEL PARK, PA 15102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
3
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 26, 2012
Abate by
Jul 31, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to collapse hazards:
(a) Jobsite: 8530 Perry Highway, Pittsburgh, PA 15102: On or about March
16, 2012,
employees were setting approximately 58 to 62 foot wooden parallel chord
trusses at a building
complex. The top chord of the roof trusses was braced at approximately 13
feet 5 inches from
the front of the building and at 13 feet 8 inches from the rear instead of
being braced at the
beginning/ending and repeating every 15 feet on center, spacing lumber
also used as bracing
under the top chord was butted together instead of overlapping two
trusses, and a spreader bar
measuring 24 feet 6 inches in length was used instead of a spreader bar
measuring 40 or more
feet in length as required by the Wood Council of America and Truss Plate
Institute Guidelines
outlined in Building Component Safety Information, BCSI-B1 and BSCI-B7:
Guide for Handling,
Installing, Restraining, and Bracing Trusses, dated 2006 and updated in
June 2011. The parallel
chord trusses were not uniformly braced over their entire installed
length. These conditions
caused the parallel chord trusses to collapse.
Among other methods, one feasible and acceptable means of abatement is to
follow the
recommendation of the component manufacturer, along with the Wood Truss
Council of America
and Truss Plate Institute guidelines outlined in the Building Component
Safety Information,
BSCI-B1: Guide for Handling, Installing, Restraining, and Bracing of
Trusses and the BCSI-B7:
Temporary and Permanent Restraint/Bracing for Parallel Chord Trusses,
dated 2006 and updated
in June 2011.
Recent events (2)
  • — I (S) $2100.00
  • — Z (S) $4200.00

1926.501 B14

Serious Gravity 05 1 instance 3 exposed
Issued
Jul 26, 2012
Abate by
Jul 31, 2012
Penalty
Initial $3,600 · Current $1,800 Reduced
Recent events (2)
  • — I (S) $1800.00
  • — Z (S) $3600.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315565127.