Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARPENTER CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARPENTER CO. in 5150 FRONTAGE RD. S, LAKELAND, FL 33815 (NAICS 326150). OSHA activity number 315570499.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carpenter CO. — free Get an email when a new federal OSHA severe-injury report for Carpenter CO. is published. One employer, no account, unsubscribe in one click.
Establishment
CARPENTER CO.
Site address
5150 FRONTAGE RD. S
City
LAKELAND
State
FL
ZIP
33815
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
SIC code (legacy)
3086
Employees
120
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 8 exposed
Issued
Aug 10, 2011
Abate by
Oct 17, 2011
Penalty
Initial $3,400 · Current $2,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that are likely to cause burns, serious injury or death in that employees
are exposed to fire
and explosion hazards.
a) Two cyclones, with a total volume of 487 cubic feet each, separated
polyurethane dust from the incoming air stream which was pulled by two 60hp
fans to remove dust from the recycle storage bins. The dust that was
suspended in and moving through the cyclones was combustible with a Kst of
16.72 bar/m*s. The cyclones were located inside the main building near the
grinding equipment in an area where employees worked on a daily basis. No
deflagration panels, vented to the outside, or other explosion protection
was
installed on the cyclones. Employees working in the area were in danger of
fire or explosion hazards associated with the combustible dust being
handled
by the cyclone.
b) Two 487 cubic feet cyclones vented exhaust air to the building and there
was no filter to capture dust in the exhaust stream or means to prevent
transmission of flame and/or explosion energy from the exhaust duct to the
building. Employees working in the area were at risk of being burned from
the
flame front coming out of the recycle duct. The dust being exhausted to the
building in the air stream had a Kst of 16.72 bar/m*s.
ABATEMENT NOTE: Among other methods, one feasible and acceptable
method to correct these hazards is to comply with the National Fire
Protection
Agency NFPA 654 "Standard for the Prevention of Fire and Dust Explosions
from the Manufacturing, Processing, and Handling of Combustible Particulate
Solids 2006 Edition" NFPA 68 "Standard on Explosion Protection by
Deflagration Venting" and NFPA 69 "Standard on Explosion Prevention
Systems 2008 edition"; including but not limited to: (a) Install explosion
relief
venting on all cyclones venting to an outside area (no more than 20 ft.
straight
duct) with no potential to be occupied by employees or install a
suppression
system in all cyclones (b) Install filters for the exhaust from the
cyclonic dust
collector/separator to ensure that filtering efficiency is 99.9% efficient
at 10
microns.
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $3400.00

1910.147 C05 IID

Deleted Serious Gravity 05 1 instance 11 exposed
Issued
Aug 10, 2011
Abate by
Aug 22, 2011
Penalty
Initial $3,400
Recent events (2)
  • — I (S)
  • — Z (S) $3400.00

1910.147 E03

Deleted Serious Gravity 05 1 instance 11 exposed
Issued
Aug 10, 2011
Abate by
Aug 22, 2011
Recent events (2)
  • — I (S)
  • — Z (S)

1910.147 C06 IC

Other-than-serious Gravity 05 1 instance 11 exposed
Issued
Aug 10, 2011
Abate by
Aug 23, 2011
Penalty
Initial $3,740
Recent events (2)
  • — I (O)
  • — Z (S) $3740.00

1910.147 C06 II

Other-than-serious Gravity 05 1 instance 11 exposed
Issued
Aug 10, 2011
Abate by
Aug 27, 2011
Recent events (2)
  • — I (O)
  • — Z (S)

1910.215 A04

Serious Gravity 05 1 instance 10 exposed
Issued
Aug 10, 2011
Abate by
Aug 16, 2011
Penalty
Initial $3,400 · Current $2,500 Reduced
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $3400.00

1910.215 B09

Repeat Gravity 02 1 instance 4 exposed
Issued
Aug 10, 2011
Abate by
Aug 15, 2011
Penalty
Initial $20,000 · Current $13,000 Reduced
Recent events (2)
  • — I (R) $13000.00
  • — Z (R) $20000.00

View Carpenter CO.'s full OSHA safety record →