BROOKSHIRE, TX —
OSHA Inspection: M-POWER CHEMICALS L C
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of M-POWER CHEMICALS L C in 30653 F.M. 529, BROOKSHIRE, TX 77423 (NAICS 325998). OSHA activity number 315571844.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M-POWER CHEMICALS L C
- Site address
- 30653 F.M. 529
- City
- BROOKSHIRE
- State
- TX
- ZIP
- 77423
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- SIC code (legacy)
- 2819
- Employees
- 29
- Ownership type
- A
Citations
18 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential dust explosion, deflagration and fire hazards caused by the insufficient collection of dust: Located in Production, the dust collection system was insufficient to control fugitive dust. Among feasible methods to correct the identified hazard, one method would be to provide continuous suction to minimize the escape of dust for processes where combustible dust is liberated in normal production operations per NFPA 654: Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, Section 8.1.1.
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
5(a)(1)
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential dust explosion, deflagration and fire hazards caused by the dust collection ducts being constructed from combustible material: Located in Production, the ventilation ducts were constructed from a combustible PVC pipe. Among feasible methods to correct the identified hazard, one method would be to construct the dust collection ducts from a non-combustible material such as sheet metal per NFPA 91: Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids, Section 4.2.1.
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
5(a)(1)
- Issued
- Oct 19, 2011
- Abate by
- Oct 24, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential dust explosion, deflagration and fire hazards caused by the bulk intermediate bags not being electrically grounded: Located in Production, bulk container bags such as calcium stearate and 363 were not electrically grounded when emptying the bags. Among feasible methods to correct the identified hazard, one method would be to install a grounding wire at the emptying station per NFPA 654: Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, Section 9.3.3.1
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
1910.22 A01
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
1910.176 C
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.26 C03 I
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
1910.95 C01
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $3,500 · Current $2,100 Reduced
Recent events (2)
- — I (S) $2100.00
- — Z (S) $3500.00
1910.134 C01
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $2,800 · Current $1,680 Reduced
Recent events (2)
- — I (S) $1680.00
- — Z (S) $2800.00
1910.134 E01
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $2,800 · Current $1,680 Reduced
Recent events (2)
- — I (S) $1680.00
- — Z (S) $2800.00
1910.134 F02
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $2,800 · Current $1,680 Reduced
Recent events (2)
- — I (S) $1680.00
- — Z (S) $2800.00
1910.134 K01
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $2,800 · Current $1,680 Reduced
Recent events (2)
- — I (S) $1680.00
- — Z (S) $2800.00
1910.145 C03
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $3,500 · Current $2,100 Reduced
Recent events (2)
- — I (S) $2100.00
- — Z (S) $3500.00
1910.178 C02 VII
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
1910.307 B
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $4,900 · Current $2,940 Reduced
Recent events (2)
- — I (S) $2940.00
- — Z (S) $4900.00
1910.1000 C
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
- Penalty
- Initial $2,100 · Current $1,260 Reduced
Recent events (2)
- — I (S) $1260.00
- — Z (S) $2100.00
1910.1000 E
- Issued
- Oct 19, 2011
- Abate by
- Dec 1, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.134 D01
- Issued
- Oct 19, 2011
- Abate by
- Oct 24, 2011
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 E01 I
- Issued
- Oct 19, 2011
- Abate by
- Nov 1, 2011
Recent events (2)
- — I (O)
- — Z (O)
More inspections at M-Power Chemicals L C
View M-Power Chemicals L C's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315571844.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.