OSHA Inspection: ICE CREAM SPECIALTIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ICE CREAM SPECIALTIES, INC. in 8419 HANLEY INDUSTRIAL CT., ST. LOUIS, MO 63144 (NAICS 311520). OSHA activity number 315596148.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ICE CREAM SPECIALTIES, INC.
- Site address
- 8419 HANLEY INDUSTRIAL CT.
- City
- ST. LOUIS
- State
- MO
- ZIP
- 63144
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311520
- SIC code (legacy)
- 2024
- Employees
- 100
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
12 citations on file for this inspection.
1910.119 D03 II
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices: Establishment: a. The employer based all its process safety management practices on international institute of ammonia refrigeration (IIAR) recognized generally accepted good engineering practices; the process safety information (PSI) did not specify the support and protection of ammonia piping smaller than 1/2 inch, such as the 1/4 inch piping used on compressors and ammonia system connections in the machine room, to prevent damage to the piping system. b. Ammonia Systems: There was no documentation on how valves installations were conducted according to manufacturers' specifications on proper torquing on flange bolts as required by the RAGAGEPS (IIAR) followed by the establishment. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.119 E03 V
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,410 · Current $2,205 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address facility siting: Engine Room: Quarter inch piping which was not addressed in the process hazard analysis for the establishment was used in ammonia systems. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $2205.00
- — Z (S) $4410.00
1910.119 J02
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment: Establishment: a. Mechanical integrity (MI)program of the process safety management practices did not consist of established procedures for inspecting ammonia piping systems and the frequency of such inspections. b. The MI program in place did not establish procedures for inspecting equipment, such as pumps, compressors, and related parts for excessive vibrations and the frequency of such inspections. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.119 J04 I
- Issued
- Sep 29, 2011
- Abate by
- Oct 4, 2011
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(i): Inspections and tests were not performed on process equipment to maintain its mechanical integrity: Rooftop: Inspections of piping systems were not conducted to prevent problems such as the violent vibration of piping systems observed on the purger line around condensers units # 1 to # 3. Arctic freezer area: A piece of process equipment, a damaged pressure gauge, was not inspected to determine its mechanical integrity.
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.119 J04 II
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: Establishment: Inspection and testing of process equipment such as, but not limited to, safety interlock systems did not follow any recognized and generally accepted good engineering practices. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.119 J04 III
- Issued
- Sep 29, 2011
- Abate by
- Oct 4, 2011
General-duty citation text
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment to maintain its mechanical integrity, was not consistent with applicable manufacturers' recommendations and good engineering practices, or more frequently determined to be necessary by prior operating experience: Establishment: Ammonia sensors in place in areas such as, the Mezzanine and machine room were not tested or calibrated within the frequency recommended by the manufacturer, Pure-Aire Monitoring Systems Inc., of every 6 months. Records indicated that the sensors were last calibrated in March, 2010. This was not consistent with the instructions of the International Institute of Ammonia Refrigeration followed by the employer. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
1910.119 J04 IV
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900
General-duty citation text
29 CFR 1910.119(j)(4)(iv): There was no documentation of any testing performed on process equipment to maintain its mechanical integrity: Establishment: A process equipment, damaged pressure gauge, was not inspected and tested to determine its mechanical integrity.
Recent events (2)
- — I (S)
- — Z (S) $4900.00
1910.119 J05
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (as defined by process information in 29 CFR 1910.119(d) before further use or in a safe and timely manner: Rooftop: Adequate remedial action was not provided on piping system with rusted gaskets and flange bolts. Receiver area: Adequate remedial action was not accorded a rusted and pitted elbow of an ammonia pipe. Arctic freezer area: Valve # 101 was not changed within the specified frequency. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $2450.00
- — Z (S) $4900.00
1910.134 B03
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.134(b)(3): Users of respirators were not instructed and trained in the proper use of respirators and their limitations: Establishment: Employees who used tight-fitting respirators were not provided required training prior to using the respirators. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $1487.50
- — Z (S) $2975.00
1910.134 E01
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Ammonia Systems: Employees who used tight-fitting respirators for ammonia gas and were expected to use the respirators for emergency purposes were not provided medical evaluation prior to using respirators. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed wih the citations.ion
1910.134 F02
- Issued
- Sep 29, 2011
- Abate by
- Nov 1, 2011
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: Ammonia Systems area: Employees who used tight-fitting respirators and were expected to use the respirators for emergency purposes were not fit tested. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
1910.23 C01
- Issued
- Sep 9, 2011
- Abate by
- Dec 31, 2011
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: Roof top area: Areas of the roof where employees were exposed to fall hazards, approximately 30 feet to the ground, were not guarded. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $3500.00
- — Z (S) $7000.00
More inspections at ICE Cream Specialties, INC.
View ICE Cream Specialties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311520)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315596148.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.