OSHA Inspection: KAUFMAN STAIRS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KAUFMAN STAIRS, INC. in 150 E. INMAN AVE., RAHWAY, NJ 07065 (NAICS 321918). OSHA activity number 315641423.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kaufman Stairs, INC. — free Get an email when a new federal OSHA severe-injury report for Kaufman Stairs, INC. is published. One employer, no account, unsubscribe in one click.
Site address
150 E. INMAN AVE.
City
RAHWAY
State
NJ
ZIP
07065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
SIC code (legacy)
2431
Employees
44
Ownership type
A
Industry flags
Manufacturing safety.

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 23, 2012
Abate by
Jul 15, 2013
Penalty
Initial $5,390 · Current $2,965 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of fire and/or explosion:
a) Kaufman Stairs Rahway, NJ - Manufacturing - Dust Collection System
containing
Class II combustible wood dust:
Employees are exposed to the hazard of fire and/or explosion resulting
from the ignition
of the contents of the dust collection system because the system was not
adequately
maintained, cleaned and serviced.
1) All components of the dust collection system were not of
non-combustible materials,
such as but not limited to, non-combustible flexible connectors/hoses.
2) The dust collection system was not provided with a spark detection
system.
3) The dust collection system was not equipped with a deflagration
suppression system.
4) An inspection, testing and maintenance program was not established for
the dust
collection system.
5) Records relating to the dust collection system were not retained and
made available
to OSHA upon request.
Condition noted on or about 2/10/2012.
ABATEMENT NOTES:
Among others, one feasible and acceptable method for abating this hazard
would be to comply
with the guidelines outlined in the National Fire Protection
Association(NFPA) 664 Standard for
the Prevention of Fires and Explosions in Wood Processing and Woodworking
Facilities (2007
Edition)
Reference: National Fire Protection Association NFPA 664 (2007 Edition)
Standard for the Prevention of Fires/Explosions in Wood Processing and
Woodworking
Facilities:
Section:664 8.2.2.2.1 - General Requirements for Duct work.
664 8.2.2.2.2 - Spark Detection System.
664 8.2.2.5.3 - Deflagration Suppression System.
664 10.2.4.1  - Inspection, Testing and Maintenance.
664 10.3.2    - Retention of required dust collection records.
Recent events (3)
  • — P (S) $2964.50
  • — I (S) $2964.50
  • — Z (S) $5390.00

1910.22 A01

Serious Gravity 05 2 instances 44 exposed
Issued
Apr 23, 2012
Abate by
May 17, 2012
Penalty
Initial $3,080 · Current $1,694 Reduced
Recent events (2)
  • — I (S) $1694.00
  • — Z (S) $3080.00

1910.37 A03

Serious Gravity 05 1 instance 36 exposed
Issued
Apr 23, 2012
Abate by
May 21, 2012
Penalty
Initial $3,080 · Current $1,694 Reduced
Recent events (2)
  • — I (S) $1694.00
  • — Z (S) $3080.00

1910.147 C04 II

Serious Gravity 05 1 instance 2 exposed
Issued
Apr 23, 2012
Abate by
May 17, 2012
Penalty
Initial $3,080 · Current $1,694 Reduced
Recent events (2)
  • — I (S) $1694.00
  • — Z (S) $3080.00

1910.147 C06 I

Serious Gravity 05 1 instance 2 exposed
Issued
Apr 23, 2012
Abate by
May 17, 2012
Recent events (2)
  • — I (S)
  • — Z (S)

1910.178 L04 III

Serious Gravity 05 1 instance 3 exposed
Issued
Apr 23, 2012
Abate by
Apr 26, 2012
Penalty
Initial $3,080 · Current $1,694 Reduced
Recent events (2)
  • — I (S) $1694.00
  • — Z (S) $3080.00

1910.213 H03

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 23, 2012
Abate by
May 17, 2012
Penalty
Initial $5,390 · Current $2,965 Reduced
Recent events (2)
  • — I (S) $2964.50
  • — Z (S) $5390.00

1910.303 B08 I

Serious Gravity 05 2 instances 36 exposed
Issued
Apr 23, 2012
Abate by
May 21, 2012
Penalty
Initial $3,080 · Current $1,694 Reduced
Recent events (2)
  • — I (S) $1694.00
  • — Z (S) $3080.00

1910.307 C

Serious Gravity 05 2 instances 36 exposed
Issued
Apr 23, 2012
Abate by
Apr 15, 2013
Penalty
Initial $3,850 · Current $2,118 Reduced
Recent events (3)
  • — P (S) $2117.50
  • — I (S) $2117.50
  • — Z (S) $3850.00

1910.95 G01

Repeat Gravity 03 2 instances 4 exposed
Issued
Apr 23, 2012
Abate by
Apr 26, 2012
Penalty
Initial $7,700 · Current $4,235 Reduced
Recent events (2)
  • — I (R) $4235.00
  • — Z (R) $7700.00

View Kaufman Stairs, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315641423.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.