Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: KEEN ENERGY SERVICE RIG 30

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEEN ENERGY SERVICE RIG 30 in MOORE 2-2H, PANGBURN, AR 72121 (NAICS 213111). OSHA activity number 315655308.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keen Energy Service RIG 30 for free Get an email when a new federal OSHA severe-injury report for Keen Energy Service RIG 30 is published. One employer, no account, unsubscribe in one click.
Site address
MOORE 2-2H
City
PANGBURN
State
AR
ZIP
72121
Mailing
P.O. BOX 549, STILLWATER, OK 74076
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 1 exposed
Issued
Aug 29, 2011
Abate by
Sep 7, 2011
Penalty
Initial $3,400 · Current $2,200 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to:
On or about July 21, 2011, employees were exposed to fall hazards where
the wire rope
used for the Geronimo line system had the wire rope clips attached with
U-bolts that
were not orientated properly. Employees were exposed to the hazards
associated with
being struck by and falls. Among others, one feasible and acceptable
method of
abatement would be to comply with API RP 9B "Recommended Practice for
Occupational Safety for Oil and Gas Well Drilling and Servicing
Operations" for the safe
manner to attach the wire rope clips.
Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the
abatement date, the
employer must submit documentation describing the actions it is taking to
establish a safe
method to correct the hazard.
Recent events (2)
  • · I (S) $2200.00
  • · Z (S) $3400.00

1910.215 B09

Other-than-serious Gravity 05 1 instance 1 exposed
Issued
Aug 29, 2011
Abate by
Sep 7, 2011
Penalty
Initial $3,400 · Current $2,000 Reduced
Recent events (2)
  • · I (O) $2000.00
  • · Z (S) $3400.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 315655308.