PINEVILLE, NC —
OSHA Inspection: RUTLAND PLASTIC TECHNOLOGIES, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of RUTLAND PLASTIC TECHNOLOGIES, INC. in 10021 RODNEY STREET, PINEVILLE, NC 28134 (NAICS 325211). OSHA activity number 315685297.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUTLAND PLASTIC TECHNOLOGIES, INC.
- Site address
- 10021 RODNEY STREET
- City
- PINEVILLE
- State
- NC
- ZIP
- 28134
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- SIC code (legacy)
- 2821
- Employees
- 87
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
4 citations on file for this inspection.
95012901
- Issued
- Sep 13, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of fire and explosion: a)mixing area, the process equipment (including the Sly dust collector) did not contain explosion protection, such as but not limited to: deflagration venting, suppression systems, isolation devices, and pressure relief systems. b)mixing area, the building and area contained combustible Polyvinyl Chloride (PVC) resin dust; the employer did not install a system to control fugitive dust from the equipment into the surrounding environment and did not implement measures to minimize dust accumulations in the area. c)mixing area, the building and area containing combustible PVC resin dust did not contain fire walls, fire partitions, and was not designed with damage-limiting construction including deflagration venting or explosion relief venting. d)mixing area, Sly dust collector utilized for combustible PVC resin dust; metal drums used to collect the dust were not bonded and grounded. e)mixing area, the employer did not develop an inspection, testing, and maintenance program to control and minimize hazards associated with combustible PVC resin dust, such as but not limited to: fire and explosion protection and prevention, dust control equipment, housekeeping, potential ignition sources, electrical process, and mechanical equipment, process changes, and lubrication of bearings. NOTE: Among other methods, one feasible and acceptable method to abate this hazard is to comply with the National Fire Protection Agency (NFPA 654), "Standard for the Prevention of Fires and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids" (2006). Additional abatement methods include, but not limited to: 1-Install deflagration isolation system, pressure relief system, and/or suppression system (from the dust collector, piping, mixers). 2-Install a ventilation system to capture fugitive emissions from the mixing stations and convey the dust to the dust collector.3-Install pressure relief system so that deflagration venting is to a safe location. 4-Bond and ground the metal drums to the dust collector. 5-Develop procedures to include an inspection, testing, and maintenance program to control and minimize the hazards associated with combustible PVC resin dust.
Recent events (2)
- — J (S) $1000.00
- — Z (S) $2800.00
1910.22 A01
- Issued
- Sep 13, 2011
- Abate by
- Dec 9, 2011
- Penalty
- Initial $2,800 · Current $1,000 Reduced
Recent events (2)
- — J (S) $1000.00
- — Z (S) $2800.00
1910.1200 H01
- Issued
- Sep 13, 2011
- Abate by
- Oct 28, 2011
- Penalty
- Initial $2,800 · Current $1,000 Reduced
Recent events (2)
- — J (S) $1000.00
- — Z (S) $2800.00
1910.134 C02 I
- Issued
- Sep 13, 2011
- Abate by
- Sep 21, 2011
Recent events (2)
- — J (O)
- — Z (O)
More inspections at Rutland Plastic Technologies, INC.
View Rutland Plastic Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315685297.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.