LUBBOCK, TX ·
OSHA Inspection: GANDY'S DAIRIES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GANDY'S DAIRIES, LLC in 201 UNIVERSITY AVENUE, LUBBOCK, TX 79415 (NAICS 311511). OSHA activity number 315714618.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GANDY'S DAIRIES, LLC
- Site address
- 201 UNIVERSITY AVENUE
- City
- LUBBOCK
- State
- TX
- ZIP
- 79415
- Mailing
- 201 UNIVERSITY AVENUE, LUBBOCK, TX 79415
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- SIC code (legacy)
- 2026
- Employees
- 130
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
20 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $2,300 Reduced
General-duty citation text
Section 5(A)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On or about January 30, 2012 and at times prior thereto, on the north wall in the maintenance break room Lubbock, Texas, employees exposed to electric hazards when an outlet was within 6 feet of a sink without a GFCI. Among other methods, feasible and acceptable abatement would be to installed a GFCI on the outlet within 6 feet of the sink.
Recent events (2)
- · I (S) $2300.00
- · Z (S) $3300.00
1910.36 G02
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1910.36(g)(2): The exit access was not atleast 28 inches (71.1 cm) wide at all points: On or about January 30, 2012 and at times prior thereto, in the packaging area Lubbock, Texas, employees were exposed to fire hazards when the exit access was 16 inches wide.s
Recent events (2)
- · I (S) $3300.00
- · Z (S) $3300.00
1910.37 A03
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free from obstructions. On or about January 30, 2012 and at times prior thereto, the exit door on the east wall in the ice cream vault Lubbock, Texas was obstructed by pallets exposing employees to fire hazards.s
Recent events (2)
- · I (S) $3300.00
- · Z (S) $3300.00
1910.119 D03 IB
- Issued
- Jul 26, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $3,300 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information pertaining to the equipment in the process did not include the piping and instrument diagrams (P&ID'S): On or about January 30, 2012 and at times prior thereto, P & IDs were not updated to reflect accurate location of pressure relief devices.
Recent events (2)
- · I (S) $2800.00
- · Z (S) $3300.00
1910.119 E05
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not establish a system to promptly address the process hazard analysis team's findings and recommendations: On or about January 30, 2012 and at times prior thereto, the employer did not ensure the process hazard analysis team's findings and recommendations were addressed promptly. a) Recommendation #1, from the 2009 Process Hazard Analysis for 1.5.6: Test compressor high sides annually. b) Recommendation #4, from the 2009 Process Hazard Analysis for 1.3.2: Review all liquid lines and determine where NH3 could be trapped by closing two valves. c) Recommendation #6. from the 2009 Process Hazard Analysis for 1.4.2: Consider piping oil drain from the ice builder to the suction side of the suction accumulator VS-104. d) Recommendation #7, from the 2009 Process Hazard Analysis for 1.5.18: Include correct valve settings for 1275 & 1276 valves in the SOPs. e) Recommendation #9, from the 2009 Process Hazard Analysis for 1.5.20: Install reseating regulator around valve 2166. f) Recommendation #10, from the 2009 Process Hazard Analysis for 1.5.20: Lockout/tagout in open position valves 2165 & 2166. g) Recommendation #11, from the 2009 Process Hazard Analysis for 1.6.10: Pipe SRV vent lines for GC-101 (including oil pot & surge drum) to 15' above the roof and at least 20' from an intake vent.
Recent events (2)
- · I (S) $4900.00
- · Z (S) $7000.00
1910.119 F01 I
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safety conducting activities in each covered process consistent with the process safety information and which addressed the elements listed in 29 CFR 1910.119(f)(1)(i) through (f)(1)(v): On or about January 30, 2012 and times prior thereto, employees were exposed to chemical hazards when the employer did not establish and implement written procedures.
Recent events (2)
- · I (S) $3850.00
- · Z (S) $5500.00
1910.119 J02
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment: On or about January 31, 2012 and times prior thereto, in the compressor room, employees were exposed to corrosive chemical hazards such as anhydrous ammonia when the employer did not establish and implement written procedures to maintain the on-going mechanical integrity of the process equipment on compressors.
Recent events (2)
- · I (S) $4400.00
- · Z (S) $4400.00
1910.119 J04 II
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: On or about January 31, 2012 and at time prior thereto, employees were exposed to corrosive chemical hazards such as anhydrous ammonia when the employer did not complete external corrosion under insulation (CUI) inspections according to generally accepted good engineering practices.g
Recent events (2)
- · I (S) $4400.00
- · Z (S) $4400.00
1910.119 N
- Issued
- Jul 26, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.119(n): The employer's emergency action plan did not include procedures for handling small releases: On or about January 30, 2012 and at times prior thereto, the employer did not ensure that procedures for ammonia release was included in the emergency action plan.
Recent events (2)
- · I (S) $4900.00
- · Z (S) $7000.00
1910.157 C01
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not provided and mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about January 31, 2012 and at times prior thereto, in the warehouse Lubbock, Texas, employees were exposed to fire hazards when a fire extinguisher was blocked by a work station.
Recent events (2)
- · I (O) $2300.00
- · Z (S) $3300.00
1910.178 Q01
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $4,400 · Current $3,080 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Powered industrial truck(s) not in safe operating conditions were not removed from service: On or about January 30, 2012 and at times prior thereto, at the back of the case dock area Lubbock, Texas, employees were exposed to caught in between hazards when Humech 50, serial #222035A forklift had a damaged rear tire.
Recent events (2)
- · I (S) $3080.00
- · Z (S) $4400.00
1910.212 A01
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: On or about January 30, 2012 and at times prior thereto, employees were exposed to rotating parts while operating equipment without guards in the production areas in the plant, Lubbock, Texas. a) The pump located in the homogenizing production area. b) The pump located in the CIP area. c) The back label machine for the gallon jugs located in the gallon blow mold area. d) The motor that pulls the chain around the track located on the west wall in the cooler area. These conditions exposed employees to caught by hazards.
Recent events (2)
- · I (O) $2300.00
- · Z (S) $3300.00
1910.303 B02
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about January 30, 2012 and at times prior thereto, on the south wall of the distribution office Lubbock, Texas, employees were exposed to electrical hazards when a Datagard surge protector power strip was used to supply electric current to a coffee pot and microwave.
Recent events (2)
- · I (O) $2300.00
- · Z (S) $3300.00
1910.303 H03
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
General-duty citation text
29 CFR 1910.303(h)(3): Sufficient space was not provided and/or maintained about electric equipment to permit ready and safe operation and/or maintenance of such equipment: On or about January 30 2012 and at times prior thereto, at the case dock area Lubbock, Texas, employees were exposed to electrical hazards when the electrical panel boxes were blocked by milk crates.
1910.305 B01 II
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Initial $3,300 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about January 30, 2012 and at times prior thereto, employees exposed to electric hazards. a) Corrugated box room: Southwest corner, an opening in a 6 outlet receptacle was not effectively closed. b) Compressor room: An opening in an electric junction box on the intercooler VS106 was not effectively closed. c) Plate Chiller-HTST: An opening in an electric junction box on the glycol plate chiller for the blow mold was not effectively closed.
Recent events (2)
- · I (S) $2300.00
- · Z (S) $3300.00
1910.305 G02 III
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that strain relief was provided which would have prevented pull from being directly transmitted to joints or terminal screws: On or about January 30, 2012 and at times prior thereto, on the east wall of the maintenance shop Lubbock, Texas, employees were exposed to electric hazards when the flexible cord on the bench grinder was pulled from the strain relief.
1910.36 G02
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Current $3,300
Recent events (3)
- · Q $3300.00
- · I (S) $3300.00
- · Z (S) $3300.00
1910.37 A03
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
Recent events (3)
- · Q $3300.00
- · I (S)
- · Z (S) $3300.00
1910.119 J02
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
- Penalty
- Current $4,400
Recent events (3)
- · Q $4400.00
- · I (S) $4400.00
- · Z (S) $4400.00
1910.119 J04 II
- Issued
- Jul 26, 2012
- Abate by
- Aug 7, 2012
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: On or about January 31, 2012 and at time prior thereto, employees were exposed to corrosive chemical hazards such as anhydrous ammonia when the employer did not complete external corrosion under insulation (CUI) inspections according to generally accepted good engineering practices.g
Recent events (3)
- · Q $4400.00
- · I (S)
- · Z (S) $4400.00
More inspections at Gandy'S Dairies, LLC
View Gandy'S Dairies, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311511)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 315714618.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.