PRESCOTT, AZ ·
OSHA Inspection: ROVER COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROVER COMPANY in 20 KIJI DAVA CIRCLE, PRESCOTT, AZ 86301 (NAICS 326199). OSHA activity number 315715698.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROVER COMPANY
- Site address
- 20 KIJI DAVA CIRCLE
- City
- PRESCOTT
- State
- AZ
- ZIP
- 86301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3999
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 15, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $4,200 · Current $850 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of exploding plastic compressed air lines: (a)In the shop area, the employer was transporting above ground compressed air through schedule 40, 1120 polyvinyl chloride (PVC) pipes. The PVC pipe is used to supply compressed air throughout the facility. This condition exposed the employees to the hazard of being struck by plastic shrapnel if the pipe fails. Among other methods, two feasible and acceptable abatement methods to correct this hazard are to: (1)Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipe can be used for transportation of compressed air and gases only if the PVC pipe is made of shatter resistant material or are encased in a shatter resistant material. (2)Replace all existing PVC pipes with a cast iron or other type of metal type piping rated to transport compressed air above ground. Abatement Note: Abatement certification and documentation are required for this citation item. See enclosed "Abatement Certification" form.fication"
Recent events (2)
- · F (S) $850.00
- · Z (S) $4200.00
1910.212 A01
- Issued
- Sep 15, 2011
- Abate by
- Sep 29, 2011
- Penalty
- Initial $3,000 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $3000.00
1910.305 G01 IVA
- Issued
- Sep 15, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,800 · Current $500 Reduced
Recent events (2)
- · F (S) $500.00
- · Z (S) $1800.00
1910.303 B02
- Issued
- Sep 15, 2011
- Abate by
- Oct 10, 2011
Recent events (2)
- · F (S)
- · Z (S)
1910.303 G01 IC
- Issued
- Sep 15, 2011
- Abate by
- Sep 29, 2011
- Penalty
- Initial $1,800 · Current $500 Reduced
Recent events (2)
- · F (S) $500.00
- · Z (S) $1800.00
1910.305 B01 II
- Issued
- Sep 15, 2011
- Abate by
- Oct 10, 2011
- Penalty
- Initial $1,800 · Current $500 Reduced
Recent events (2)
- · F (S) $500.00
- · Z (S) $1800.00
1910.303 B07
- Issued
- Sep 15, 2011
- Abate by
- Oct 10, 2011
Recent events (2)
- · F (O)
- · Z (O)
More inspections at Rover Company
View Rover Company's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315715698.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.